Comparison of in-phase and opposed-phase GRE and conventional SE MR pulse sequences in T1-weighted imaging of liver lesions

被引:26
作者
Martin, J
Sentis, M
Puig, J
Rue, M
Falco, J
Donoso, L
Zidan, A
机构
[1] CONSORCI HOSP PARC TAULI,SERV DIAGNOST IMATGE,BARCELONA,SPAIN
[2] CONSORCI HOSP PARC TAULI,DEPT EPIDEMIOL,BARCELONA,SPAIN
关键词
liver; neoplasms; diseases; magnetic resonance imaging; comparative studies; rapid; chemical shift;
D O I
10.1097/00004728-199611000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Our goal was to compare in-phase (IF) and opposed-phase (OF) GRE and conventional SE sequences in T1-weighted (T1-W) imaging of the liver and to evaluate chemical shift GRE imaging in characterizing liver/lesions for fat content. Method: LP and OP T1-W GRE with fast low angle shot (FLASH) technique and T1-W SE sequences were compared in 162 patients at 1.0 T. Chemical shift GRE imaging was used to characterize lesions with fat content. Two hundred sixteen lesions were analyzed in three groups of liver: (a) ''normal'' liver (n = 74 with 110 lesions); (b) cirrhotic liver (n = 76 with 85 lesions), and (c) fatty liver (n = 12 with 21 lesions). Liver/lesion contrast and liver/lesion contrast-to-noise ratio were assessed for lesion detectability. The percentage of signal intensity variation (SIV) between IP and OP images was used to characterize lesions for fat content. Results: The OP GRE sequence had significantly higher contrast for normal and cirrhotic livers (p < 0.001), and the IP GRE sequence had significantly higher contrast and contrast-to-noise ratio for fatty liver (p < 0.001). There were no significant differences between OP, IF, and TI-W SE imaging in cirrhotic cases for contrast-to-noise ratio (p < 0.28). Chemical shift imaging detected fat in 21 lesions (9.7%, mean SIV, 191.1%) (sensitivity and specificity 100% when compared with fine needle aspiration cytology). Conclusion: OP GRE sequences could replace conventional SE sequences in T1-W imaging in nonfatty livers, whereas in fatty livers, T1-W SE sequences could be obviated, but both OP and IP sequences are necessary. Chemical shift imaging (OF and IP) can be used to accurately characterize lesions for fat content.
引用
收藏
页码:890 / 897
页数:8
相关论文
共 23 条
[1]   MR-IMAGING OF THE LIVER - BREATH-HOLD T1-WEIGHTED MP-GRE COMPARED WITH CONVENTIONAL T2-WEIGHTED SE IMAGING - LESION DETECTION, LOCALIZATION, AND CHARACTERIZATION [J].
DELANGE, EE ;
MUGLER, JP ;
BOSWORTH, JE ;
DEANGELIS, GA ;
GAY, SB ;
HURT, NS ;
BERR, SS ;
ROSENBLATT, JM ;
MERICKEL, LW ;
HARRIS, EK .
RADIOLOGY, 1994, 190 (03) :727-736
[2]   MR IMAGING OF SMALL HEPATOCELLULAR-CARCINOMA - EFFECT OF INTRATUMORAL COPPER CONTENT ON SIGNAL INTENSITY [J].
EBARA, M ;
WATANABE, S ;
KITA, K ;
YOSHIKAWA, M ;
SUGIURA, N ;
OHTO, M ;
KONDO, F ;
KONDO, Y .
RADIOLOGY, 1991, 180 (03) :617-621
[3]   DYNAMIC MR IMAGING OF THE LIVER WITH GD-DTPA - INITIAL CLINICAL-RESULTS [J].
EDELMAN, RR ;
SIEGEL, JB ;
SINGER, A ;
DUPUIS, K ;
LONGMAID, HE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) :1213-1219
[4]   SEGMENTED TURBOFLASH - METHOD FOR BREATH-HOLD MR IMAGING OF THE LIVER WITH FLEXIBLE CONTRAST [J].
EDELMAN, RR ;
WALLNER, B ;
SINGER, A ;
ATKINSON, DJ ;
SAINI, S .
RADIOLOGY, 1990, 177 (02) :515-521
[5]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[6]   MULTIPLE HEPATORENAL ANGIOMYOLIPOMAS - DIAGNOSIS WITH FAT-SUPPRESSION, GADOLINIUM-ENHANCED MRI [J].
HOOPER, LD ;
MERGO, PJ ;
ROS, PR .
ABDOMINAL IMAGING, 1994, 19 (06) :549-551
[7]   CT AND MR IMAGING OF FATTY TUMORS OF THE LIVER [J].
ITAI, Y ;
OHTOMO, K ;
KOKUBO, T ;
MAKITA, K ;
OKADA, Y ;
MACHIDA, T ;
YASHIRO, N .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (02) :253-257
[8]   FATTY METAMORPHOSIS OF HEPATOCELLULAR-CARCINOMA DETECTION WITH CHEMICAL-SHIFT GRADIENT-ECHO MR-IMAGING [J].
MARTIN, J ;
SENTIS, M ;
ZIDAN, A ;
DONOSO, L ;
PUIG, J ;
FALCO, J ;
BELLA, R .
RADIOLOGY, 1995, 195 (01) :125-130
[9]   RAPID ACQUISITION SPIN-ECHO (RASE) MR IMAGING - A NEW TECHNIQUE FOR REDUCTION OF ARTIFACTS AND ACQUISITION TIME [J].
MIROWITZ, SA ;
LEE, JKT ;
BROWN, JJ ;
EILENBERG, SS ;
HEIKEN, JP ;
PERMAN, WH .
RADIOLOGY, 1990, 175 (01) :131-135
[10]  
MITCHELL DG, 1992, RADIOLOGY, V185, P1