Statistical framework for ultrasonic spectral parameter imaging

被引:117
作者
Lizzi, FL [1 ]
Astor, M [1 ]
Feleppa, EJ [1 ]
Shao, M [1 ]
Kalisz, A [1 ]
机构
[1] COLUMBIA UNIV COLL PHYS & SURG,NEW YORK,NY 10032
关键词
ultrasonic spectrum analysis; ultrasonic parameter images; prostate ultrasonography; liver ultrasonography; integrated backscatter;
D O I
10.1016/S0301-5629(97)00200-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study examines the statistics of ultrasonic spectral parameter images that are being used to evaluate tissue microstructure in several organs, The parameters are derived from sliding-window spectrum analysis of radiofrequency echo signals, Calibrated spectra are expressed in dB and analyzed with linear regression procedures to compute spectral slope, intercept and midband fit, which is directly related to integrated backscatter, Local values of each parameter are quantitatively depicted in gray-scale cross-sectional images to determine tissue type, response to therapy and physical scatterer properties, In this report, we treat the statistics of each type of parameter image for statistically homogeneous scatterers, Probability density functions are derived for each parameter, and theoretical results are compared with corresponding histograms clinically measured in homogeneous tissue segments in the liver and prostate, Excellent agreement was found between theoretical density functions and data histograms for homogeneous tissue segments, Departures from theory are observed in heterogeneous tissue segments, The results demonstrate how the statistics of each spectral parameter and integrated backscatter are related to system and analysis parameters, These results are now being used to guide the design of system and analysis parameters, to improve assays of tissue heterogeneity and to evaluate the precision of estimating features associated with effective scatterer sizes and concentrations. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1371 / 1382
页数:12
相关论文
共 24 条
[1]   Error bounds on ultrasonic scatterer size estimates [J].
Chaturvedi, P ;
Insana, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 100 (01) :392-399
[2]  
DAVENPORT WB, 1958, INTRO THEORY RANDOM, P113
[3]   DIAGNOSTIC SPECTRUM ANALYSIS IN OPHTHALMOLOGY - A PHYSICAL PERSPECTIVE [J].
FELEPPA, EJ ;
LIZZI, FL ;
COLEMAN, DJ ;
YAREMKO, MM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (08) :623-631
[4]   Typing of prostate tissue by ultrasonic spectrum analysis [J].
Feleppa, EJ ;
Kalisz, A ;
SokilMelgar, JB ;
Lizzi, FL ;
Liu, T ;
Rosado, AL ;
Shao, MC ;
Fair, WR ;
Wang, Y ;
Cookson, MS ;
Reuter, VE ;
Heston, WDW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (04) :609-619
[5]  
GRADSHTEYN IS, 1980, TABLE INTEGRALS SERI, P576
[6]   Precision and accuracy of acoustospectrographic parameters [J].
Huisman, HJ ;
Thijssen, JM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (07) :855-871
[7]   DESCRIBING SMALL-SCALE STRUCTURE IN RANDOM-MEDIA USING PULSE-ECHO ULTRASOUND [J].
INSANA, MF ;
WAGNER, RF ;
BROWN, DG ;
HALL, TJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (01) :179-192
[8]  
KAPLAN D, 1994, P IEEE ULTR S, P961
[9]   VARIATION OF ACOUSTIC ATTENUATION COEFFICIENT SLOPE ESTIMATES FOR INVIVO LIVER [J].
KUC, R ;
TAYLOR, KJW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (04) :403-412
[10]  
LINDGREN BW, 1962, STAT THEORY, P31