Grafted and segmented hydrophilic polyimides for microfiltration membranes II. Fouling measurements

被引:7
作者
Bourne, H
Eastmond, GC
Gibas, M
Pacynko, WF
Paprotny, J
机构
[1] Univ Liverpool, Dept Chem, Liverpool L693BX, Merseyside, England
[2] BP Int Ltd, Sunbury Res Ctr, Sunbury On Thames TW16 7LN, Middx, England
关键词
hydrophilic polyimide; fouling; protein adsorption; membrane; poly(ethylene oxide);
D O I
10.1016/S0376-7388(01)00749-9
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper describes the use of hydrophilic grafted and segmented copolyimides to modify the surfaces of polyimide membranes used for microfiltration processes the synthesis and characterisation of the copolymers are described in an accompanying paper. The copolymers have either hydrophilic grafts or hydrophilic main-chain segments based on poly(ethylene oxide). Samples for fouling studies were prepared by incorporating a proportion of copolymer while forming a membrane from a hydrophobic polyimide. Both grafted and segmented copolyimides reduced fouling as assessed by measurements of protein (radio-labelled bovine serum albumin) absorption. Fouling propensities were investigated for different copolymer contents and compositions. Variations in composition included changes in the aromatic dianhydrides and aromatic diamines used in conjunction with the hydrophilic units. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:17 / 27
页数:11
相关论文
共 17 条
[1]  
Cho DL, 1997, POLYM-KOREA, V21, P142
[2]  
EASTMOND GC, IN PRESS J MEMBR SCI
[3]   Preparation of protein-resistant surfaces on poly(vinylidene fluoride) membranes via surface segregation [J].
Hester, JF ;
Banerjee, P ;
Mayes, AM .
MACROMOLECULES, 1999, 32 (05) :1643-1650
[4]  
Hwang TS, 2000, POLYM-KOREA, V24, P621
[5]   SURFACE MODIFICATION OF KAPTON FILM BY PLASMA TREATMENTS [J].
INAGAKI, N ;
TASAKA, S ;
HIBI, K .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1992, 30 (07) :1425-1431
[6]   Fouling and protein adsorption effect of low-temperature plasma treatment of membrane surfaces [J].
J. Ohansson ;
H. K. Yasuda ;
R. K. Bajpai .
Applied Biochemistry and Biotechnology, 1998, 70-72 (1) :747-763
[7]   PERVAPORATION OF WATER-ETHANOL MIXTURE THROUGH HYDROPHILICALLY MODIFIED POLYIMIDE MEMBRANE [J].
KANG, YS ;
JUNG, BS ;
KIM, UY .
MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1993, 224 :137-146
[8]   Temperature-sensitive membranes prepared by UV photopolymerization of N-isopropylacrylamide on a surface of porous hydrophilic polypropylene membranes [J].
Liang, L ;
Feng, XD ;
Peurrung, L ;
Viswanathan, V .
JOURNAL OF MEMBRANE SCIENCE, 1999, 162 (1-2) :235-246
[9]   SURFACE MODIFICATION OF POLYIMIDE FILMS BY GRAFT-COPOLYMERIZATION [J].
LOH, FC ;
LAU, CB ;
TAN, KL ;
KANG, ET .
JOURNAL OF APPLIED POLYMER SCIENCE, 1995, 56 (13) :1707-1713
[10]   Membrane fouling reduction by backpulsing and surface modification [J].
Ma, HM ;
Bowman, CN ;
Davis, RH .
JOURNAL OF MEMBRANE SCIENCE, 2000, 173 (02) :191-200