Long-term follow-up (11 years plus) results of JRI (Furlong) total hip arthroplasty in young patients: cause for concern regarding acetabular cup?

被引:14
作者
Sharma, D. K.
Brooks, Stuart
机构
[1] Birmingham Heartlands Hosp, Birmingham B9 5ST, W Midlands, England
[2] Solihull Hosp, Birmingham, W Midlands, England
关键词
D O I
10.1007/s00264-006-0083-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We describe the clinical and radiological long-term outcomes of 77 primary total hip replacements in 69 patients using the fully hydroxyapatite-coated JRI (Furlong) total hip replacement. The total cases followed up were 77 hips, performed at a mean duration of 11 years and 2 months. Twelve hips could not be followed up for various reasons, which are discussed in the results section. The mean Harris hip score was 89. Seventeen acetabular cups were revised for aseptic loosening. Only one femoral stem was revised, for fracture. By Engh's criteria there were a further two unstable cups with no symptoms, and all femoral stems were stable. Kaplan-Meier survivorship analysis revealed a survival of 98.8% for the femoral stem, 78.7% for the acetabular cup, and a combined survival of 77.8% for both components. Our findings suggest that the JRI (Furlong) hip gives a durable femoral stem implant fixation, whereas the prosthesis-bone interface achieved with the acetabular component is questionable.
引用
收藏
页码:375 / 380
页数:6
相关论文
共 16 条
[1]
BLOEBAUM RD, 1993, J ARTHROPLASTY, V8, P203, DOI 10.1016/S0883-5403(09)80014-4
[2]
Hydroxyapatite in total hip arthroplasty -: Clinical results and critical issues [J].
Capello, WN ;
D 'Antonio, JA ;
Manley, MT ;
Feinberg, JR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (355) :200-211
[3]
MECHANICAL AND HISTOLOGICAL-EVALUATION OF HYDROXYAPATITE-COATED, TITANIUM-COATED AND GRIT-BLASTED SURFACES UNDER WEIGHT-BEARING CONDITIONS [J].
DAVID, A ;
EITENMULLER, J ;
MUHR, G ;
POMMER, A ;
BAR, HF ;
OSTERMANN, PAW ;
SCHILDHAUER, TA .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1995, 114 (02) :112-118
[4]
Radiological and survival comparison of four methods of fixation of a proximal femoral stem [J].
Donnelly, WJ ;
Kobayashi, A ;
Freeman, MAR ;
Chin, TW ;
Yeo, H ;
West, M ;
Scott, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03) :351-360
[5]
POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[6]
FIXATION OF HIP PROSTHESES BY HYDROXYAPATITE CERAMIC COATINGS [J].
FURLONG, RJ ;
OSBORN, JF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :741-745
[7]
The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups -: From the Norwegian Arthroplasty Register [J].
Havelin, LI ;
Espehaug, B ;
Engesæter, LB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (06) :839-845
[8]
HOFMANN AA, 1993, J ARTHROPLASTY, V8, P157, DOI 10.1016/S0883-5403(06)80056-2
[9]
Total hip arthroplasty with hydroxyapatite-coated prostheses [J].
Jaffe, WL ;
Scott, DF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (12) :1918-1934
[10]
Failure of hydroxyapatite-coated acetabular cups - Ten-year follow-up of 85 Landos Atoll arthroplasties [J].
Lai, KA ;
Shen, WJ ;
Chen, CH ;
Yang, CY ;
Hu, WP ;
Chang, GL .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :641-646