Comprehensive MR imaging in the preoperative evaluation of living donor candidates for laparoscopic nephrectomy: Initial experience

被引:38
作者
Israel, GM
Lee, VS
Edye, M
Krinsky, GA
Lavelle, MT
Diflo, T
Weinreb, JC
机构
[1] NYU, Med Ctr, Dept Radiol, New York, NY 10016 USA
[2] NYU, Med Ctr, Dept Surg, New York, NY 10016 USA
关键词
kidney; MR; transplantation; renal arteries;
D O I
10.1148/radiol.2252011671
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the accuracy of magnetic resonance (MR) imaging in the preoperative evaluation of potential living renal donors who are candidates for laparoscopic nephrectomy. MATERIALS AND METHODS: Twenty-eight donor candidates who underwent subsequent laparoscopic nephrectomy were examined by using a torso phased-array coil at 1.5 T. Gadollinium-enhanced MR angiograms, MR venograms, and MR urograms were obtained in all patients by using an interpolated three-dimensional T1-weighted spoiled gradient-echo sequence (3.4-6.8/1.2-2.3 [repetition, time msec/echo time msec], 25degrees-40degrees flip angle). Interpretation of the MR images was used to assess the arterial, venous, and ureteral anatomy, as well as parenchymal masses and scarring, and findings were compared with the surgical findings in all patients. Statistical evaluation was performed, with the surgical findings as the reference standard. RESULTS: At MR imaging, 31 of 32 renal arteries and one of three early-branching arteries were identified correctly. The correct venous anatomy was identified in 23 of 28 patients, including a single left renal vein anterior to the aorta (n = 16), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 2), and single right renal vein (n = 3). A single collecting system in all harvested kidneys was identified correctly with MR.urography. Overall, MR imaging correctly depicted vascular, ureteral, and parenchymal anatomy in 21 of 28 patients. Twenty-seven of 28 patients underwent successful laparoscopic donor nephrectomy on the basis of the MR findings. One procedure was converted to open nephrectomy on the basis of complex venous anatomy not prospectively identified on the MR images. The sensitivity and positive predictive value of MR imaging in correctly determining the combined vascular, ureteral, and parenchymal anatomy in the harvested kidney were 75% (21 of 28) and 95% (21 of 22), respectively. CONCLUSION: Comprehensive gadolinium-enhanced MR imaging can depict the vascular anatomy, collecting system, and renal parenchyma preoperatively in patients who are candidates for laparoscopic living-donor nephrectomy. (C) RSNA, 2002.
引用
收藏
页码:427 / 432
页数:6
相关论文
共 20 条
[1]   Renal artery stenosis and accessory renal arteries:: Accuracy of detection and visualization with gadolinium-enhanced breath-hold MR angiography [J].
Bakker, J ;
Beek, FJA ;
Beutler, JJ ;
Hené, RJ ;
de Kort, GAP ;
de Lange, EE ;
Moons, KGM ;
Mali, WPTM .
RADIOLOGY, 1998, 207 (02) :497-504
[2]   Helical CT angiography for examination of living renal donors [J].
Cochran, ST ;
Krasny, RM ;
Danovitch, GM ;
Rajfer, J ;
Barbaric, ZM ;
Wilkinson, A ;
Rosenthal, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) :1569-1573
[3]   Helical CT examination of potential kidney donors [J].
Dachman, AH ;
Newmark, GM ;
Mitchell, MT ;
Woodle, ES .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) :193-200
[4]   Helical computerized tomography arteriography for evaluation of live renal donors undergoing laparoscopic nephrectomy [J].
Del Pizzo, JJ ;
Sklar, GN ;
You-Cheong, JW ;
Levin, B ;
Krebs, T ;
Jacobs, SC .
JOURNAL OF UROLOGY, 1999, 162 (01) :31-34
[5]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[6]   Strategies for making more organs available for transplantation [J].
Gridelli, B ;
Remuzzi, G .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (06) :404-410
[7]   Preoperative evaluation of living renal donors: Comparison of CT angiography and MR angiography [J].
Halpern, EJ ;
Mitchell, DG ;
Wechsler, RJ ;
Outwater, EK ;
Moritz, MJ ;
Wilson, GA .
RADIOLOGY, 2000, 216 (02) :434-439
[8]   Accuracy of normal-dose contrast-enhanced MR angiography in assessing renal artery stenosis and accessory renal arteries [J].
Korst, MBJM ;
Joosten, FBM ;
Postma, CT ;
Jager, GJ ;
Krabbe, JK ;
Barentsz, JO .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (03) :629-634
[9]  
LJUNGHALL S, 1987, MINER ELECTROL METAB, V13, P220
[10]   Potential renal transplant donors: Evaluation with gadolinium-enhanced MR angiography and MR urography [J].
Low, RN ;
Martinez, AG ;
Steinberg, SM ;
Alzate, GD ;
Kortman, KE ;
Bower, BB ;
Dwyer, WJ ;
Prince, SK .
RADIOLOGY, 1998, 207 (01) :165-172