Quadricepsplasty after war fractures

被引:11
作者
Jovanovic, S [1 ]
Orlic, D [1 ]
Wertheimer, B [1 ]
Zelic, Z [1 ]
Has, B [1 ]
机构
[1] Osijek Univ Hosp, Dept Orthoped Surg, HR-31000 Osijek, Croatia
关键词
D O I
10.1093/milmed/165.4.263
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Knee movements after fractures caused by explosive devices, as well as after intra-articular fractures of the knee, are often inadequate. This paper presents the results of quadricepsplasty performed in 10 patients with the purpose of improving knee function. All of the patients were treated by the external fixation method, either after femoral fractures caused by explosive devices or for intra-articular knee fractures. All of them manifested markedly decreased knee flexion (15-70 degrees, with an average of 32 degrees). After quadricepsplasty and physical therapy, the achieved knee flexion was enough for normal walking (80-130 degrees, average 97.5 degrees). Mean knee mobility was increased 65.5 degrees. Our paper presents indications, methods, results, and complications for quadricepsplasty performed after war injuries.
引用
收藏
页码:263 / 267
页数:5
相关论文
共 13 条
[11]
RATLIFF AHC, 1972, INJURY, V4, P126, DOI 10.1016/0020-1383(72)90010-1
[12]
THOMAS FB, 1972, INJURY, V4, P137, DOI 10.1016/0020-1383(72)90012-5
[13]
Thompson TC, 1944, J BONE JOINT SURG, V26, P366