Phase-resolved frequency domain optical Doppler tomography

被引:2
作者
Wang, L [1 ]
Wang, Y [1 ]
Bachman, M [1 ]
Li, GP [1 ]
Chen, ZP [1 ]
机构
[1] Univ Calif Irvine, Dept Elect Engn & Comp Sci, Irvine, CA 92717 USA
来源
COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII | 2004年 / 5316卷
关键词
optical Doppler tomography; flowmetry;
D O I
10.1117/12.531421
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a phase-resolved optical Doppler tomography (ODT) system at 13 10 nm using frequency domain method. Frequency domain phase-resolved ODT potentially allows for an increased longitudinal imaging range, signal-to-noise ratio and imaging acquisition rates, which can dramatically increase the measurable velocity dynamic range. A detailed derivation of phase-resolved frequency domain ODT and a measurement of flow through micro channel are presented. This technique can be used to quantify flow in integrated microfluidic devices in which complex three-dimensional structures and a wide velocity range are present.
引用
收藏
页码:432 / 438
页数:7
相关论文
共 16 条
[1]   Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media [J].
Chen, ZP ;
Milner, TE ;
Dave, D ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (01) :64-66
[2]   Optical coherence tomography using a frequency-tunable optical source [J].
Chinn, SR ;
Swanson, EA ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (05) :340-342
[3]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[4]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[5]   High-resolution optical coherence tomography over a large depth range with an axicon lens [J].
Ding, ZH ;
Ren, HW ;
Zhao, YH ;
Nelson, JS ;
Chen, ZP .
OPTICS LETTERS, 2002, 27 (04) :243-245
[6]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[7]  
Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
[8]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[9]   Differential spectral interferometry: an imaging technique for biomedical applications [J].
Vakhtin, AB ;
Peterson, KA ;
Wood, WR ;
Kane, DJ .
OPTICS LETTERS, 2003, 28 (15) :1332-1334
[10]  
WANG L, 2004, IN PRESS P SPIE, P5345