Determination of glomerular filtration rate using a dual-detector gamma camera and the geometric mean of renal activity - Correlation with the Tc-99m DTPA plasma clearance method
被引:12
作者:
Delpassand, ES
Homayoon, K
Madden, T
Mathai, M
Podoloff, DA
机构:
[1] Univ Texas, MD Anderson Canc Ctr, Dept Nucl Med, Div Diagnost Imaging, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Div Pediat, Houston, TX 77030 USA
关键词:
glomerular filtration rate;
kidney;
Tc-99m DTPA;
D O I:
10.1097/00003072-200004000-00004
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: In this study, the authors studied the use of a dual-detector gamma camera to measure the glomerular filtration rate (GFR). Methods: Thirty-three patients with a wide range of renal function participated in this study. The GFR was measured using a dual-detector gamma camera by calculating the geometric mean of activity from each kidney and using an outline background. These results were compared with the GFR estimates obtained from Tc-99m DTPA plasma clearance using a multiple blood sample method. Results: Correlation was excellent between GFR estimated using the dual-detector gamma camera and GFR measured using the plasma clearance of Tc-99m DTPA with multiple blood samples (r = 0.89). The correlation was especially strong in children younger than 13 years (r = 0.94). Conclusion: Measuring the GFR using a dual-detector gamma camera and calculating the geometric mean of renal activity yields relatively accurate results.
引用
收藏
页码:258 / 262
页数:5
相关论文