Evolution of dry powder inhaler design, formulation, and performance

被引:234
作者
Newman, SP
Busse, WW
机构
[1] Pharmaceut Profiles Ltd, Nottingham NG11 6JS, England
[2] Univ Wisconsin, Madison Med Sch, Madison, WI USA
关键词
asthma; inhaler devices; dry powder inhalers;
D O I
10.1053/rmed.2001.1276
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Many companies are now prioritizing the development of dry powder inhalers (DPIs) above pressurized formulations of asthma drugs. A well-designed DPI and an appropriate powder formulation can optimize the effectiveness of inhaled drug therapy A DPI must be able to deliver medications effectively for most patients, and an ideal inhaler would provide a dose that does not vary with inspiratory flow rate, Recent regulatory guidelines, among which the U.S.FDA draft guidance is the most stringent, demand consistent dose delivery from an inhaler throughout its life and consistency of doses from one inhaler to another. However, the properties of free micronized powders often interfere with drug handling and with drug delivery, reducing dose consistency. Recent advances in formulation technology can increase lung dose and reduce its variability. While a perfect DPI may never exist, both device and formulation technology are evolving to rectify perceived deficiencies in earlier systems. (C) 2002 Elsevier Science Ltd.
引用
收藏
页码:293 / 304
页数:12
相关论文
共 90 条
[1]   WHAT DO PEDIATRICIANS IN-TRAINING KNOW ABOUT THE CORRECT USE OF INHALERS AND SPACER DEVICES [J].
AMIRAV, I ;
GOREN, A ;
PAWLOWSKI, NA .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1994, 94 (04) :669-675
[2]  
[Anonymous], EUROPEAN PHARM S
[3]  
[Anonymous], RESP DRUG DELIVERY
[4]  
[Anonymous], ADV PHARM SCI
[5]  
Ashurst I, 2000, Pharm Sci Technol Today, V3, P246, DOI 10.1016/S1461-5347(00)00275-3
[6]   DRY POWDER AEROSOLS .1. NEW POWDER INHALATION DEVICE [J].
BELL, JH ;
HARTLEY, PS ;
COX, JSG .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1971, 60 (10) :1559-&
[7]  
BERNER B, 1998, RESP DRUG DELIVERY, V6, P475
[8]   Automatic actuation of a dry powder inhaler into a nonelectrostatic spacer [J].
Bisgaard, H .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (02) :518-521
[9]  
BLAIR J, 2000, RESP DRUG DELIVERY, V7, P481
[10]   Safety and efficacy of a high cumulative dose of salbutamol inhaled via Turbuhaler® or via a pressurized metered-dose inhaler in patients with asthma [J].
Bondesson, E ;
Friberg, K ;
Soliman, S ;
Lofdahl, CG .
RESPIRATORY MEDICINE, 1998, 92 (02) :325-330