Evolution of dry powder inhaler design, formulation, and performance

被引:234
作者
Newman, SP
Busse, WW
机构
[1] Pharmaceut Profiles Ltd, Nottingham NG11 6JS, England
[2] Univ Wisconsin, Madison Med Sch, Madison, WI USA
关键词
asthma; inhaler devices; dry powder inhalers;
D O I
10.1053/rmed.2001.1276
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Many companies are now prioritizing the development of dry powder inhalers (DPIs) above pressurized formulations of asthma drugs. A well-designed DPI and an appropriate powder formulation can optimize the effectiveness of inhaled drug therapy A DPI must be able to deliver medications effectively for most patients, and an ideal inhaler would provide a dose that does not vary with inspiratory flow rate, Recent regulatory guidelines, among which the U.S.FDA draft guidance is the most stringent, demand consistent dose delivery from an inhaler throughout its life and consistency of doses from one inhaler to another. However, the properties of free micronized powders often interfere with drug handling and with drug delivery, reducing dose consistency. Recent advances in formulation technology can increase lung dose and reduce its variability. While a perfect DPI may never exist, both device and formulation technology are evolving to rectify perceived deficiencies in earlier systems. (C) 2002 Elsevier Science Ltd.
引用
收藏
页码:293 / 304
页数:12
相关论文
共 90 条
[61]  
Olsson B., 1996, RESP DRUG DELIVERY, P273
[62]  
OSTRANDER KD, 2000, RESP DRUG DELIVERY, V7, P447
[63]  
PARRYBILLINGS M, 2001, EUR PHARM CONTRACTOR, P42
[64]   METERED-DOSE INHALERS AND CFCS - WHAT RESPIRATORY PHYSICIANS NEED TO KNOW [J].
PARTRIDGE, MR .
RESPIRATORY MEDICINE, 1994, 88 (09) :645-647
[65]  
PATTON JS, 1995, Patent No. 5458135
[66]   Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers [J].
Pauwels, R ;
Newman, S ;
Borgstrom, L .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (09) :2127-2138
[67]  
PEART J, 1996, RESP DRUG DELIVERY, V5, P85
[68]  
PERSSON G, 1989, EUR RESPIR J, V2, P253
[69]   A COMPARISON OF THE LUNG DEPOSITION OF SALBUTAMOL INHALED FROM A NEW DRY POWDER INHALER, AT 2 INHALED FLOW-RATES [J].
PITCAIRN, G ;
LUNGHETTI, G ;
VENTURA, P ;
NEWMAN, S .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1994, 102 (1-3) :11-18
[70]   Scintigraphic assessment of drug delivery from the ultrahaler dry powder inhaler [J].
Pitcairn, GR ;
Lim, J ;
Hollingworth, A ;
Newman, SP .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1997, 10 (04) :295-306