Reproducibility of RTVue Retinal Nerve Fiber Layer Thickness and Optic Disc Measurements and Agreement with Stratus Optical Coherence Tomography Measurements

被引:196
作者
Gonzalez-Garcia, Alberto O. [1 ]
Vizzeri, Gianmarco [1 ]
Bowd, Christopher [1 ]
Medeiros, Felipe A. [1 ]
Zangwill, Linda M. [1 ]
Weinreb, Robert N. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
基金
美国国家卫生研究院;
关键词
GLAUCOMATOUS EYES; HIGH-SPEED; OCT;
D O I
10.1016/j.ajo.2008.12.032
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE: To evaluate RTVue spectral-domain optical coherence tomography (OCT) (Optovue Inc, Fremont, California, USA) reproducibility and to assess agreement with Stratus time-domain OCT (Carl Zeiss Meditec, Dublin, California, USA) measurements. DESIGN: Observational clinical study. METHODS: Scans were obtained from both eyes of all participants 3 times using the RTVue nerve head map 4-mm diameter protocol and once using Stratus OCT within the same session. RTVue reproducibility and agreement with Stratus OCT were evaluated for retinal nerve fiber layer (RNFL) and optic disc measurements. RESULTS: Thirty healthy participants (60 eyes) and 38 glaucoma patients (76 eyes) were included in the study. RTVue reproducibility was good in both healthy participants and patients. For average RNFL thickness, the intraclass correlation coefficients in healthy eyes and patient eyes were 0.97 whereas for rim area they were 0.97 and 0.96, respectively. The correlation between RTVue and Stratus measurements generally was good, especially for average RNFL thickness (healthy eyes and patient eyes, r(2) = 0.82 and 0.86, respectively) and rim volume (healthy eyes and patient eyes, r(2) = 0.78 and 0.76, respectively). Bland-Altman plots showed good agreement between the instruments, with better agreement for average RNFL thickness (95% limits of agreement in healthy eyes and patient eyes, -8.6 to 12 mu m and -5.6 to -14.8 mu m, respectively) than optic disc parameters. Cup-to disc ratio 95% limits of agreement in healthy eyes and patient eyes were -0.3 to 0.4 and -0.2 to 0.3, respectively. Optic disc measurements with RTVue were smaller than those with Stratus OCT (eg, disc area was on average 0.4 mm(2) smaller and rim area was 0.3 mm(2) smaller with RTVue). CONCLUSIONS: Reproducibility of RTVue RNFL and optic disc measurements was excellent in both groups. The level of agreement between RTVue and Stratus measurements suggests that RTVue has the potential to detect glaucomatous structural changes. (Am J Ophthalmol 2009; 147:1067-1074. (C) 2009 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:1067 / 1074
页数:8
相关论文
共 21 条
[1]
Quantitative assessment of structural damage in eyes with localized visual field abnormalities [J].
Bagga, H ;
Greenfield, DS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (05) :797-805
[2]
Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography [J].
Blumenthal, EZ ;
Williams, JM ;
Weinreb, RN ;
Girkin, CA ;
Berry, CC ;
Zangwill, LM .
OPHTHALMOLOGY, 2000, 107 (12) :2278-2282
[3]
Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes [J].
Budenz, DL ;
Chang, RT ;
Huang, XR ;
Knighton, RW ;
Tielsch, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2440-2443
[4]
Sensitivity and specificity of the StratusOCT for perimetric glaucoma [J].
Budenz, DL ;
Michael, A ;
Chang, RT ;
McSoley, J ;
Katz, J .
OPHTHALMOLOGY, 2005, 112 (01) :3-9
[5]
Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes [J].
Budenz, Donald L. ;
Fredette, Marie-Josee ;
Feuer, William J. ;
Anderson, Douglas R. .
OPHTHALMOLOGY, 2008, 115 (04) :661-666
[6]
Spectral domain optical coherence tomography - Ultra-high speed, ultra-high resolution ophthalmic imaging [J].
Chen, TC ;
Cense, B ;
Pierce, MC ;
Nassif, N ;
Park, BH ;
Yun, SH ;
White, BR ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (12) :1715-1720
[7]
Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography [J].
Cheung, Carol Yim Lui ;
Leung, Christopher Kai Shun ;
Lin, Dusheung ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2008, 115 (08) :1347-1351
[8]
Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[9]
New technology for high-speed and high-resolution optical coherence tomography [J].
Fujimoto, JG ;
Bouma, B ;
Tearney, GJ ;
Boppart, SA ;
Pitris, C ;
Southern, JF ;
Brezinski, ME .
ADVANCES IN OPTICAL BIOPSY AND OPTICAL MAMMOGRAPHY, 1998, 838 :95-107
[10]
Statistical analysis of correlated data using generalized estimating equations: An orientation [J].
Hanley, JA ;
Negassa, A ;
Edwardes, MDD ;
Forrester, JE .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2003, 157 (04) :364-375