Multi-elemental characterization of soft biological tissues by inductively coupled plasma-sector field mass spectrometry

被引:80
作者
Engström, E
Stenberg, A
Senioukh, S
Edelbro, R
Baxter, DC
Rodushkin, I
机构
[1] Analyt AB, S-97775 Lulea, Sweden
[2] Lulea Univ Technol, Div Appl Geol, S-97187 Lulea, Sweden
关键词
biological tissues; inductively coupled plasma-sector field mass spectrometry; multi-elemental analysis; digestion;
D O I
10.1016/j.aca.2004.06.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of double-focusing, sector field ICP-MS (ICP-SFMS) for the multi-elemental analysis of soft tissues following microwave-assisted digestion with nitric acid was evaluated and factors affecting method limits of detection discussed. Accuracy was assessed by replicate analyses of certified reference materials and by participation in performance evaluation programs; the precision was better than 5% relative standard deviation (RSD) for the majority of elements. Cl was the only element for which ICP-SFMS data consistently deviated from certified concentrations in the reference materials tested. Comparison between results obtained by ICP-SFMS and ICP optical emission spectrometry showed good agreement for elements present in tissues at concentrations above 2 mug g(-1). The concentrations of 68 elements in different fish and animal soft tissues (muscle, liver, kidney, lung and brain) are presented, and, where possible, compared with previously published data. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 135
页数:13
相关论文
共 43 条
[21]   Metal (Fe, Zn, Mn and Cu) levels in the Antarctic fish Notothenia coriiceps [J].
Márquez, M ;
Vodopivez, C ;
Casaux, R ;
Curtosi, A .
POLAR BIOLOGY, 1998, 20 (06) :404-408
[22]  
MATHEWS CK, 2000, BIOCHEMISTRY-US, P360
[23]  
MILLER JC, 1988, STAT ANAL CHEM, P137
[24]   NEW HIGH-RESOLUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY TECHNOLOGY APPLIED FOR THE DETERMINATION OF V, FE, CU, ZN AND AG IN HUMAN SERUM [J].
MOENS, L ;
VERREPT, P ;
DAMS, R ;
GREB, U ;
JUNG, G ;
LASER, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :1075-1078
[25]   Extraction and characterisation of trace element species from porcine liver samples using online HPLC-ICP-MS and offline HPLC-ESI-MS [J].
Nischwitz, V ;
Michalke, B ;
Kettrup, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :444-451
[26]   The contribution of inductively coupled plasma mass spectrometry to biomedical research [J].
Patriarca, M .
MICROCHEMICAL JOURNAL, 1996, 54 (03) :262-271
[27]   Determination of low concentrations of potentially toxic elements in human liver from newborns and infants [J].
Patriarca, M ;
Lyon, TDB ;
Delves, HT ;
Howatson, AG ;
Fell, GS .
ANALYST, 1999, 124 (09) :1337-1343
[28]   Correlations of trace element levels within and between different normal autopsy tissues analyzed by inductively coupled plasma atomic emission spectrometry (ICP-AES) [J].
Rahil-Khazen, R ;
Bolann, BJ ;
Ulvik, RJ .
BIOMETALS, 2002, 15 (01) :87-98
[29]   Determination of 60 elements in whole blood by sector field inductively coupled plasma mass spectrometry [J].
Rodushkin, I ;
Ödman, F ;
Olofsson, R ;
Axelsson, MD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) :937-944
[30]  
RODUSHKIN I, 2001, RRD PURE APPL CHEM, V5, P51