A dosimetric analysis of dose escalation using two intensity-modulated radiation therapy techniques in locally advanced pancreatic carcinoma

被引:68
作者
Brown, Michael W.
Ning, Holly
Arora, Barbara
Albert, Paul S.
Poggi, Matthew
Camphausen, Kevin
Citrin, Deborah
机构
[1] NCI, ROB, CRC, CCR, Bethesda, MD 20892 USA
[2] NIH, Biometr Res Branch, Div Canc Treatment & Diag, Bethesda, MD 20892 USA
[3] Natl Naval Med Res Inst, Bethesda, MD USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 65卷 / 01期
关键词
pancreatic cancer; intensity-modulated radiation therapy (IMRT); dose escalation;
D O I
10.1016/j.ijrobp.2006.01.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To perform an analysis of three-dimensional conformal radiation therapy (3D-CRT), sequential boost intensity-modulated radiation therapy (IMRTs), and integrated boost IMRT (IMRTi) for dose escalation in unresectable pancreatic carcinoma. Methods and Materials: Computed tomography images from 15 patients were used. Treatment plans were generated using 3D-CRT, IMRTs, and IMRTi for dose levels of 54, 59.4, and 64.8 Gy. Plans were analyzed for target coverage, doses to liver, kidneys, small bowel, and spinal cord. Results: Three-dimensional-CRT exceeded tolerance to small bowel in 1 of 15 (6.67%) patients at 54 Gy, and 4 of 15 (26.7%) patients at 59.4 and 64.8 Gy. 3D-CRT exceeded spinal cord tolerance in 1 of 15 patients (6.67%) at 59.4 Gy and liver constraints in 1 of 15 patients (6.67%) at 64.8 Gy; no IMRT plans exceeded tissue tolerance. Both IMRT techniques reduced the percentage of total kidney volume receiving 20 Gy (V20), the percentage of small bowel receiving 45 Gy (V45), and the percentage of liver receiving 35 Gy (V35). IMRTi appeared superior to IMRTs in reducing the total kidney V20 (p < 0.0001), right kidney V20 (p < 0.0001), and small bowel V45 (p = 0.02). Conclusions: Sequential boost IMRT and IMRTi improved the ability to achieve normal tissue dose goals compared with 3D-CRT. IMRTi allowed dose escalation to 64.8 Gy with acceptable normal tissue doses and superior dosimetry compared with 3D-CRT and IMRTs. (c) 2006 Elsevier Inc.
引用
收藏
页码:274 / 283
页数:10
相关论文
共 43 条
[1]   Adjuvant therapy in pancreatic cancer: Phase I trial of radiation dose escalation with concurrent full-dose gemcitabine [J].
Allen, AM ;
Zalupski, MM ;
Robertson, JM ;
Eckhauser, FE ;
Simone, D ;
Brown, D ;
Hejna, G ;
Normolle, D ;
Lawrence, TS ;
McGinn, CJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (05) :1461-1467
[2]  
[Anonymous], CANC FACTS FIG 2003
[3]   Intensity-modulated radiotherapy (IMRT) and concurrent capecitabine for pancreatic cancer [J].
Ben-Josef, E ;
Shields, AF ;
Vaishampayan, U ;
Vaitkevicius, V ;
El-Rayes, BF ;
McDermott, P ;
Burmeister, J ;
Bossenberger, T ;
Philip, PA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (02) :454-459
[4]  
BROOKS JR, 1983, SURGERY PANCREAS, P263
[5]   SURVIVAL IN 1001 PATIENTS WITH CARCINOMA OF THE PANCREAS [J].
CONNOLLY, MM ;
DAWSON, PJ ;
MICHELASSI, F ;
MOOSSA, AR ;
LOWENSTEIN, F .
ANNALS OF SURGERY, 1987, 206 (03) :366-373
[6]   Feasibility of dose escalation using intensity-modulated radiotherapy in posthysterectomy cervical carcinoma [J].
D'Souza, WD ;
Ahamad, AA ;
Iyer, RB ;
Salehpour, MR ;
Jhingran, A ;
Eifel, PJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (04) :1062-1070
[7]   Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation [J].
Dehnad, H ;
Nederveen, AJ ;
van der Heide, UA ;
van Moorselaar, RJA ;
Hofman, P ;
Lagendijk, JJW .
RADIOTHERAPY AND ONCOLOGY, 2003, 67 (03) :295-302
[8]   Assessment of different IMRT boost delivery methods on target coverage and normal-tissue sparing [J].
Dogan, N ;
King, S ;
Emami, B ;
Mohideen, N ;
Mirkovic, N ;
Leybovich, LB ;
Sethi, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (05) :1480-1491
[9]   Intensity-modulated radiation therapy for head and neck cancer: Emphasis on the selection and delineation of the targets [J].
Eisbruch, A ;
Foote, RL ;
O'Sullivan, B ;
Beitler, JJ ;
Vikram, B .
SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) :238-249
[10]  
Fu WH, 2004, WORLD J GASTROENTERO, V10, P1098