Use of spiral computed tomography for multiplanar dental reconstruction

被引:30
作者
Preda, L
DiMaggio, EM
Dore, R
LaFianza, A
Solcia, M
Schifino, MR
Campani, R
Preda, EG
机构
[1] Istituto di Radiologia, IRCCS Policlinico S Matteo, Università di Pavia, Pavia
[2] Clinica Odontoiatrica, IRCCS Policlinico S Matteo, Università di Pavia, Pavia
[3] Istituto di Radiologia, IRCCS Policlinico S Matteo, 27100 Pavia, p.le Golgi
关键词
tomography; X-ray computed; dental implantation; image processing; computer-assisted;
D O I
10.1038/sj.dmfr.4600290
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare spiral with conventional CT for multiplanar reconstruction (MPR) prior to dental implant placement. Methods: Ten patients underwent conventional and then Spiral CT at 1 mm slice thickness. In six patients (Group A) the pitch was 1:1, the other four (Group B) it was 2:1. Image quality and clinical features were evaluated separately on axial and reconstructed images by two experienced radiologists who scored each parameter from 1 (poor, non-diagnostic) to 3 (good, diagnostic). Results: Loss of spatial resolution with spiral CT was not significant and the diagnostic yield poorer only for trabecular bone structure. The MPRs were better and depiction of the mandibular canal more reliable. Conclusions: We recommend the use of spiral CT instead of conventional CT for dental MPR because examination time is shorter and patient comfort is improved. Use of a pitch of 2:1 permits a marked reduction in X-ray dose with no loss of image quality.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 13 条
[1]  
BRINK JA, 1995, RADIOL CLIN N AM, V33, P825
[2]   DENTA SCAN - CT SOFTWARE PROGRAM USED IN THE ANATOMIC EVALUATION OF THE MANDIBLE AND MAXILLA IN THE PERSPECTIVE OF ENDOSSEOUS IMPLANT-SURGERY [J].
CASSELMAN, JW ;
DERYCKERE, F ;
HERMANS, R ;
DECLERCQ, C ;
NEYT, L ;
PATTYN, G ;
MEEUS, L ;
VANDEVOORDE, P ;
STEYAERT, L ;
DEVOS, V .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (01) :4-10
[3]  
CLARK D E, 1990, Journal of Oral Implantology, V16, P156
[4]   ROLE OF DIAGNOSTIC-IMAGING IN EVALUATION OF THE DENTAL IMPLANT PATIENT [J].
DELBALSO, AM ;
GREINER, FG ;
LICATA, M .
RADIOGRAPHICS, 1994, 14 (04) :699-719
[5]  
Ekestubbe A, 1993, Dentomaxillofac Radiol, V22, P13
[6]  
HIRSCHFELDER V, 1994, ADV CT, V3, P163
[7]   RECONSTRUCTED HELICAL CT SCANS - IMPROVEMENT IN Z-AXIS RESOLUTION COMPARED WITH OVERLAPPED AND NONOVERLAPPED CONVENTIONAL CT SCANS [J].
KASALES, CJ ;
HOPPER, KD ;
ARIOLA, DN ;
TENHAVE, TR ;
MEILSTRUP, JW ;
MAHRAJ, RPM ;
VANHOOK, D ;
WESTACOTT, S ;
SEFCZEK, RJ ;
BARR, JD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1281-1284
[8]  
RIGAUTS H, 1990, ADV CT, P65
[9]  
Schmuth G P, 1992, Eur J Orthod, V14, P296
[10]  
SCHWARZ MS, 1989, DENT CLIN N AM, V33, P555