RECONSTRUCTED HELICAL CT SCANS - IMPROVEMENT IN Z-AXIS RESOLUTION COMPARED WITH OVERLAPPED AND NONOVERLAPPED CONVENTIONAL CT SCANS

被引:54
作者
KASALES, CJ
HOPPER, KD
ARIOLA, DN
TENHAVE, TR
MEILSTRUP, JW
MAHRAJ, RPM
VANHOOK, D
WESTACOTT, S
SEFCZEK, RJ
BARR, JD
机构
[1] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT RADIOL,HERSHEY,PA 17033
[2] PENN STATE UNIV,CTR BIOSTAT & EPIDEMIOL,HERSHEY,PA 17033
关键词
D O I
10.2214/ajr.164.5.7717248
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This in vitro study was designed to assess the z-axis resolving capabilities of reconstructed helical CT scans obtained with various imaging parameters versus those of conventional CT scans and the effect of decreasing slice index on the z-axis resolution of helical CT. MATERIALS AND METHODS. A z-axis line-pair phantom was imaged using conventional nonoverlapped CT scans, conventional CT scans that overlapped by 50%, and helical CT scans with pitches of 1.0 and 1.5. All helical images were reconstructed at comparable slice indexes (image indexes of 2.0, 1.0, and 0.5 mm for pitch = 1.0, and image indexes of 3.0, 1.5, and 0.75 mm for pitch = 1.5), Midline coronal and sagittal reconstructed images were obtained to allow standardized visualization of line pairs. The reconstructed images were reviewed separately by 10 radiologists. RESULTS. The overall z-axis resolution of reconstructed helical CT scans equaled or exceeded that of nonoverlapped conventional CT scans in all cases and equaled that of 50% overlapped conventional CT scans in 75% of cases. The 1.0-pitch helical sequences showed improved z-axis resolution with decreasing slice index, No statistically significant improvement in z-axis resolution could be determined by the observers for 1.5-pitch sequences with decreasing slice index. CONCLUSION. The use of helical CT with a pitch of 1.0 or 1.5 and an increased slice index can improve the z-axis resolution of reconstructed images when compared with nonoverlapped conventional CT and frequently equals the resolution of 50% overlapped conventional CT, This improvement in z-axis resolution should improve the appearance of reconstructed images (as used in CT angiography and three-dimensional imaging) by reducing partial volume artifacts while affording faster scanning at a reduced skin-surface radiation dose.
引用
收藏
页码:1281 / 1284
页数:4
相关论文
共 8 条
[1]  
FLEISS JL, 1986, DESIGN ANAL CLIN EXP, P103
[2]   A COMPARISON OF CONVENTIONAL AND SPIRAL CT - AN EXPERIMENTAL-STUDY ON THE DETECTION OF SPHERICAL LESIONS [J].
KALENDER, WA ;
POLACIN, A ;
SUSS, C .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :167-176
[3]   PHYSICAL PERFORMANCE-CHARACTERISTICS OF SPIRAL CT SCANNING [J].
KALENDER, WA ;
POLACIN, A .
MEDICAL PHYSICS, 1991, 18 (05) :910-915
[4]  
KING SH, 1993, RADIOLOGY, V189, P356
[5]   COMPARISON OF HELICAL AND SERIAL CT WITH REGARD TO 3-DIMENSIONAL IMAGING OF MUSCULOSKELETAL ANATOMY [J].
NEY, DR ;
FISHMAN, EK ;
KAWASHIMA, A ;
ROBERTSON, DD ;
SCOTT, WW .
RADIOLOGY, 1992, 185 (03) :865-869
[6]   SPIRAL CT OF THE LUNGS - OPTIMAL TECHNIQUE AND RESOLUTION COMPARED WITH CONVENTIONAL CT [J].
PARANJPE, DV ;
BERGIN, CJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (03) :561-567
[7]   EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT [J].
POLACIN, A ;
KALENDER, WA ;
MARCHAL, G .
RADIOLOGY, 1992, 185 (01) :29-35
[8]   DETECTION OF FOCAL HEPATIC-LESIONS WITH SPIRAL CT - COMPARISON OF 4-MM AND 8-MM INTERSCAN SPACING [J].
URBAN, BA ;
FISHMAN, EK ;
KUHLMAN, JE ;
KAWASHIMA, A ;
HENNESSEY, JG ;
SIEGELMAN, SS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (04) :783-785