Improving the accuracy of pulsed field gradient NMR diffusion experiments: Correction for gradient non-uniformity

被引:101
作者
Connell, Mark A. [1 ]
Bowyer, Paul J. [2 ]
Bone, P. Adam [1 ]
Davis, Adrian L. [3 ]
Swanson, Alistair G. [3 ]
Nilsson, Mathias [1 ]
Morris, Gareth A. [1 ]
机构
[1] Univ Manchester, Sch Chem, Manchester M13 9PL, Lancs, England
[2] Magnet Technol Ctr, Varian Ltd, Magnet Resonance Syst, Yarnton OX5 1QU, Oxon, England
[3] Pfizer Global Res & Dev, Sandwich CT13 9NJ, Kent, England
基金
英国工程与自然科学研究理事会;
关键词
Diffusion; Pulsed field gradients; Non-uniform field gradients; Ste[!text type='js']js[!/text]kal-Tanner equation; DOSY; MAGNETIC-RESONANCE-SPECTROSCOPY; LEAST-SQUARES ANALYSIS; HIGH-RESOLUTION NMR; SPECTRAL DATA SETS; SELF-DIFFUSION; ORDERED SPECTROSCOPY; CONVECTION COMPENSATION; PRACTICAL METHOD; LIQUID SAMPLES; DOSY DATA;
D O I
10.1016/j.jmr.2009.01.025
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Pulsed field gradient NMR is a well-established technique for the determination of self-diffusion coefficients. However, a significant source of systematic error exists in the spatial variation of the applied pulsed field gradient. Non-uniform pulsed field gradients cause the decay of peak amplitudes to deviate from the expected exponential dependence on gradient squared. This has two undesirable effects: the apparent diffusion coefficient will deviate from the true value to an extent determined by the choice of experimental parameters, and the error estimated by the nonlinear least squares fitting will contain a significant systematic contribution. In particular, the apparent diffusion coefficient determined by exponential fitting of the diffusional attenuation of NMR signals will depend both oil the exact pulse widths used and on the range of gradient amplitudes chosen. These problems can be partially compensated for if experimental attenuation data are fitted to a function corrected for the measured spatial dependence of the gradient and signal strength. This study describes a general alternative to existing methods for the calibration of NMR diffusion measurements. The dominant longitudinal variation of the pulsed field gradient amplitude and the signal strength are mapped by measuring pulsed field gradient echoes in the presence of a weak read gradient. These data are then used to construct a predicted signal decay function for the whole sample, which is parameterised as the exponential of a power series. Results are presented which compare diffusion coefficients obtained using the new calibration method with previous literature values. (C) 2009 Published by Elsevier Inc.
引用
收藏
页码:121 / 131
页数:11
相关论文
共 45 条
[31]   Speedy component resolution: An improved tool for processing diffusion-ordered spectroscopy data [J].
Nilsson, Mathias ;
Morris, Gareth A. .
ANALYTICAL CHEMISTRY, 2008, 80 (10) :3777-3782
[32]   Improved DECRA processing of DOSY data: correcting for non-uniform field gradients [J].
Nilsson, Mathias ;
Morris, Gareth A. .
MAGNETIC RESONANCE IN CHEMISTRY, 2007, 45 (08) :656-660
[33]   Pure shift proton DOSY:: diffusion-ordered 1H spectra without multiplet structure [J].
Nilsson, Mathias ;
Morris, Gareth A. .
CHEMICAL COMMUNICATIONS, 2007, (09) :933-935
[34]   A one-shot sequence for high-resolution diffusion-ordered spectroscopy [J].
Pelta, MD ;
Morris, GA ;
Stchedroff, MJ ;
Hammond, SJ .
MAGNETIC RESONANCE IN CHEMISTRY, 2002, 40 (SPEC. ISS.) :S147-S152
[35]  
Pelta MD, 1998, MAGN RESON CHEM, V36, P706, DOI 10.1002/(SICI)1097-458X(199810)36:10<706::AID-OMR363>3.0.CO
[36]  
2-W
[37]   Analytical applications of NMR diffusion measurements [J].
Price, KE ;
Lucas, LH ;
Larive, CK .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (06) :1405-1407
[38]   EFFECT OF NONRECTANGULAR FIELD GRADIENT PULSES IN THE STEJS']JSKAL AND TANNER (DIFFUSION) PULSE SEQUENCE [J].
PRICE, WS ;
KUCHEL, PW .
JOURNAL OF MAGNETIC RESONANCE, 1991, 94 (01) :133-139
[39]   2D and 3D DOSY methods for studying mixtures of oligomeric dimethylsiloxanes [J].
Stchedroff, MJ ;
Kenwright, AM ;
Morris, GA ;
Nilsson, M ;
Harris, RK .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2004, 6 (13) :3221-3227
[40]   SPIN DIFFUSION MEASUREMENTS: SPIN ECHOES IN THE PRESENCE OF A TIME-DEPENDENT FIELD GRADIENT [J].
STEJSKAL, EO ;
TANNER, JE .
JOURNAL OF CHEMICAL PHYSICS, 1965, 42 (01) :288-+