Blood pressure variability, target organ damage and cardiovascular events

被引:42
作者
Parati, G
Lantelme, P
机构
[1] Univ Milano Bicocca, Dept Clin Med Prevent & Appl Biotechnol, Cardiol Unit 2, St Luca Hosp,Ist Auxolog Italiano,Ist Sci, I-20149 Milan, Italy
[2] Hop Croix Rousse, Serv Cardiol, Hospices Civils Lyon, Fac Med, F-69317 Lyon, France
关键词
D O I
10.1097/00004872-200209000-00014
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
引用
收藏
页码:1725 / 1729
页数:5
相关论文
共 48 条
  • [1] BEVAN AT, 1969, CLIN SCI, V36, P329
  • [2] Broad-band spectral analysis of 24 h continuous finger blood pressure: comparison with intra-arterial recordings
    Castiglioni, P
    Parati, G
    Omboni, S
    Mancia, G
    Imholz, BPM
    Wesseling, KH
    Di Rienzo, M
    [J]. CLINICAL SCIENCE, 1999, 97 (02) : 129 - 139
  • [3] Conway J, 1984, J Hypertens, V2, P203, DOI 10.1097/00004872-198404000-00013
  • [4] ROLE OF BARORECEPTOR REFLEX IN DAILY CONTROL OF ARTERIAL BLOOD-PRESSURE AND OTHER VARIABLES IN DOGS
    COWLEY, AW
    LIARD, JF
    GUYTON, AC
    [J]. CIRCULATION RESEARCH, 1973, 32 (05) : 564 - 576
  • [5] Cardiovascular morbidity and mortality in the Losartan Intervention For Endpoint reduction in hypertension study (LIFE):: a randomised trial against atenolol
    Dahlöf, B
    Devereux, RB
    Kjeldsen, SE
    Julius, S
    Beevers, G
    de Faire, U
    Fyhrquist, F
    Ibsen, H
    Kristiansson, K
    Lederballe-Pedersen, O
    Lindholm, LH
    Nieminen, MS
    Omvik, P
    Oparil, S
    Wedel, H
    [J]. LANCET, 2002, 359 (9311) : 995 - 1003
  • [6] ROLE OF SINOAORTIC AFFERENTS IN MODULATING BP AND PULSE-INTERVAL SPECTRAL CHARACTERISTICS IN UNANESTHETIZED CATS
    DI RIENZO, M
    PARATI, G
    CASTIGLIONI, P
    OMBONI, S
    FERRARI, AU
    RAMIREZ, AJ
    PEDOTTI, A
    MANCIA, G
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1991, 261 (06): : H1811 - H1818
  • [7] CONTINUOUS VS INTERMITTENT BLOOD-PRESSURE MEASUREMENTS IN ESTIMATING 24-HOUR AVERAGE BLOOD-PRESSURE
    DIRIENZO, M
    GRASSI, G
    PEDOTTI, A
    MANCIA, G
    [J]. HYPERTENSION, 1983, 5 (02) : 264 - 269
  • [8] PROGNOSTIC VALUE OF 24-HOUR BLOOD-PRESSURE VARIABILITY
    FRATTOLA, A
    PARATI, G
    CUSPIDI, C
    ALBINI, F
    MANCIA, G
    [J]. JOURNAL OF HYPERTENSION, 1993, 11 (10) : 1133 - 1137
  • [9] Hales S, 1733, STATISTICAL ESSAYS C, P2
  • [10] FEASIBILITY OF AMBULATORY, CONTINUOUS 24-HOUR FINGER ARTERIAL-PRESSURE RECORDING
    IMHOLZ, BPM
    LANGEWOUTERS, GJ
    VANMONTFRANS, GA
    PARATI, G
    VANGOUDOEVER, J
    WESSELING, KH
    WIELING, W
    MANCIA, G
    [J]. HYPERTENSION, 1993, 21 (01) : 65 - 73