Initial field evaluation of the Harvard active ozone sampler for personal ozone monitoring

被引:12
作者
Geyh, AS [1 ]
Roberts, PT [1 ]
Lurmann, FW [1 ]
Schoell, BM [1 ]
Avol, EL [1 ]
机构
[1] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
来源
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY | 1999年 / 9卷 / 02期
关键词
active; children; collection; ozone; passive; personal; rate; sampler;
D O I
10.1038/sj.jea.7500001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Assessing personal exposure to ozone has only been feasible recently with the introduction of passive ozone samplers. These devices are easy to use, but changes in air velocity across their collection surfaces can affect performance. The Harvard active ozone sampler (AS) was developed in response to problems with the passive methods. This active sampler has been tested extensively as a microenvironmental sampler. To test for personal sampling, 40 children attending summer day-camp in Riverside, California wore the active ozone sampler for approximately 2.6 h on July 19 and 21, 1994. when ozone concentrations were about 100 ppb and 140 ppb. respectively. The children spent 94-100% of the sampling period outside, staying within a well-defined area while participating in normal camp activities. Ambient ozone concentrations across this area were monitored by two UV photometric ozone monitors. The active sampler was worn in a small backpack that was also equipped with a passive ozone sampler. Device precision. reported as the percent difference between duplicate pairs of samplers, was +/- 3.7% and +/- 4.2% for the active and passive samplers. respectively. The active sampler measured, on average, 94.5 +/- 8.2% of the ambient ozone while the passive samplers measured, on average, 124.5 +/- 18.8%. The samplers were worn successfully for the entire sampling period by all participating children.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 12 条
[1]  
FRITTS TW, 1985, QUALITY ASSURANCE EN, P76
[2]   Development and evaluation of a small active ozone sampler [J].
Geyh, AS ;
Wolfson, JM ;
Koutrakis, P ;
Mulik, JD ;
Avol, EL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (08) :2326-2330
[3]   A PASSIVE SAMPLER FOR ATMOSPHERIC OZONE [J].
GROSJEAN, D ;
HISHAM, MWM .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1992, 42 (02) :169-173
[4]  
HACKNEY JD, 1994, 63 HLTH EFF I, P1
[5]  
*HARV SCH PUBL HLT, 1994, PROT OZ MEAS US OZ P
[6]   PASSIVE OZONE OXIDANT SAMPLER WITH COULOMETRIC DETERMINATION USING I2/NYLON-6 CHARGE-TRANSFER COMPLEX [J].
KANNO, S ;
YANAGISAWA, Y .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (04) :744-749
[7]   MEASUREMENT OF AMBIENT OZONE USING A NITRITE-COATED FILTER [J].
KOUTRAKIS, P ;
WOLFSON, JM ;
BUNYAVIROCH, A ;
FROEHLICH, SE ;
HIRANO, K ;
MULIK, JD .
ANALYTICAL CHEMISTRY, 1993, 65 (03) :209-214
[8]  
LIPPMANN M, 1993, J EXPO ANAL ENV EPID, V3, P103
[9]   ASSESSMENT OF OZONE EXPOSURES IN THE GREATER METROPOLITAN TORONTO AREA [J].
LIU, LJS ;
KOUTRAKIS, P ;
LEECH, J ;
BRODER, I .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1995, 45 (04) :223-234
[10]   USE OF PERSONAL MEASUREMENTS FOR OZONE EXPOSURE ASSESSMENT - A PILOT-STUDY [J].
LIU, LJS ;
KOUTRAKIS, P ;
SUH, HH ;
MULIK, JD ;
BURTON, RM .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1993, 101 (04) :318-324