Diagnostic Accuracy of In-House PCR for Pulmonary Tuberculosis in Smear-Positive Patients: Meta-Analysis and Metaregression

被引:43
作者
Greco, S. [1 ]
Rulli, M. [1 ]
Girardi, E. [2 ]
Piersimoni, C. [3 ]
Saltini, C. [4 ]
机构
[1] Azienda Osped San Camillo Forlanini, Dip Malattie Polmonari, I-00151 Rome, Italy
[2] IRCCS, Dipartimento Epidemiol, INMI L Spallanzani, Rome, Italy
[3] Azienda Osped Univ Osped Riuniti, Serv Microbiol Clin, Ancona, Italy
[4] Univ Roma Tor Vergata, Dipartimento Med Interna, Rome, Italy
关键词
POLYMERASE-CHAIN-REACTION; ACID-AMPLIFICATION TESTS; MYCOBACTERIUM-TUBERCULOSIS; RESPIRATORY SPECIMENS; CLINICAL SPECIMENS; BRONCHOALVEOLAR LAVAGE; SPUTUM SPECIMENS; META-REGRESSION; RAPID DETECTION; QUALITY-CONTROL;
D O I
10.1128/JCM.02051-08
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In-house PCR (hPCR) could speed differential diagnosis between tuberculosis (TB) and nontuberculous mycobacterial disease in patients with positive smears and pulmonary infiltrates, but its reported accuracy fluctuates across studies. We conducted a systematic review and meta-analysis of hPCR sensitivity and specificity for smear-positive TB diagnosis, using culture as the reference standard. After searching English language studies in MEDLINE and EMBASE, we estimated cumulative accuracy by means of summary receiver operating characteristic analysis. The possible influence of hPCR procedures and study methodological features on accuracy was explored by univariate metaregression, followed by multivariate adjustment of items selected as significant. Thirty-five articles (1991 to 2006) met the inclusion criteria. The pooled estimates of the diagnostic odds ratio, sensitivity, and specificity (random-effect model) were, respectively, 60 (confidence interval [CI], 29 to 123), 0.96 (CI, 0.95 to 0.97), and 0.81 (CI, 0.78 to 0.84), but significant variations (mainly in specificity) limit their clinical applicability. The quality of the reference test, the detection method, and real-time PCR use explained some of the observed heterogeneity. Probably due to the limited study power of our meta-analysis and to the wide differences in both laboratory techniques and methodological quality, only real-time PCR also displayed a positive impact on accuracy in the multivariate model. Currently, hPCR can be confidently used to exclude TB in smear-positive patients, but its low specificity could lead to erroneous initiation of therapy, isolation, and contact investigation. As the inclusion of samples from treated patients could have artificially reduced specificity, future studies should report mycobacterial-culture results for each TB and non-TB sample analyzed.
引用
收藏
页码:569 / 576
页数:8
相关论文
共 60 条
  • [1] DETECTION OF MYCOBACTERIUM-TUBERCULOSIS IN CLINICAL SPECIMENS BY POLYMERASE CHAIN-REACTION AND GEN-PROBE AMPLIFIED MYCOBACTERIUM-TUBERCULOSIS DIRECT TEST
    ABE, C
    HIRANO, K
    WADA, M
    KAZUMI, Y
    TAKAHASHI, M
    FUKASAWA, Y
    YOSHIMURA, T
    MIYAGI, C
    GOTO, S
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (12) : 3270 - 3274
  • [2] Clinical evaluation of an in-house IS6110 polymerase chain reaction for diagnosis of tuberculosis
    Almeda, J
    García, A
    González, J
    Quintó, L
    Ventura, PJ
    Vidal, R
    Rufí, G
    Martínez, JA
    de Anta, MTJ
    Trilla, A
    Alonso, PL
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2000, 19 (11) : 859 - 867
  • [3] [Anonymous], 2000, JAMA, V284, P826
  • [4] In-house nucleic acid amplification assays in research: How much quality control is needed before one can rely upon the results?
    Apfalter, P
    Reischl, U
    Hammerschlag, MR
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (12) : 5835 - 5841
  • [5] Araj GF, 2000, INT J TUBERC LUNG D, V4, P877
  • [6] Comparison of culture and acid-fast bacilli stain to PCR for detection of Mycobacterium tuberculosis in clinical samples
    Aslanzadeh, J
    de la Viuda, M
    Fille, M
    Smith, WB
    Namdari, H
    [J]. MOLECULAR AND CELLULAR PROBES, 1998, 12 (04) : 207 - 211
  • [7] Quantitative real-time PCR is not more sensitive than "Conventional" PCR
    Bastien, Patrick
    Procop, Gary W.
    Reischl, Udo
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (06) : 1897 - 1900
  • [8] BRONCHOSCOPY WITH BRONCHOALVEOLAR LAVAGE IN TUBERCULOSIS AND FUNGAL-INFECTIONS
    BAUGHMAN, RP
    DOHN, MN
    LOUDON, RG
    FRAME, PT
    [J]. CHEST, 1991, 99 (01) : 92 - 97
  • [9] The STARD statement for reporting studies of diagnostic accuracy: Explanation and elaboration
    Bossuyt, PM
    Reitsma, JB
    Bruns, DE
    Gatsonis, CA
    Glasziou, PP
    Irwig, LM
    Moher, D
    Rennie, D
    de Vet, HCW
    Lijmer, JG
    [J]. CLINICAL CHEMISTRY, 2003, 49 (01) : 7 - 18
  • [10] BOYKO EJ, 1995, AM J EPIDEMIOL, V141, P680