SimPACE: Generating simulated motion corrupted BOLD data with synthetic-navigated acquisition for the development and evaluation of SLOMOCO: A new, highly effective slicewise motion correction

被引:86
作者
Beall, Erik B. [1 ]
Lowe, Mark J. [1 ]
机构
[1] Cleveland Clin, Imaging Inst, Cleveland, OH 44195 USA
关键词
Functional MRI; Functional connectivity; BOLD; Motion correction; Spin history; STIMULUS-CORRELATED MOTION; PHYSIOLOGICAL NOISE; HEAD MOTION; CORRECTION ALGORITHMS; FMRI; REGISTRATION; MRI; ARTIFACTS; SOFTWARE; SUBJECT;
D O I
10.1016/j.neuroimage.2014.06.038
中图分类号
Q189 [神经科学];
学科分类号
071006 [神经生物学];
摘要
Head motion in functional MRI and resting-state MRI is a major problem. Existing methods do not robustly reflect the true level of motion artifact for in vivo fMRI data. The primary issue is that current methods assume that motion is synchronized to the volume acquisition and thus ignore intra-volume motion. This manuscript covers three sections in the use of gold-standard motion-corrupted data to pursue an intra-volume motion correction. First, we present a way to get motion corrupted data with accurately known motion at the slice acquisition level. This technique simulates important data acquisition-related motion artifacts while acquiring real BOLD MRI data. It is based on a novel motion-injection pulse sequence that introduces known motion independently for every slice: Simulated Prospective Acquisition CorrEction (SimPACE). Secondly, with data acquired using SimPACE, we evaluate several motion correction and characterization techniques, including several commonly used BOLD signal-and motion parameter-based metrics. Finally, we introduce and evaluate a novel, slice-based motion correction technique. Our novel method, SLice-Oriented MOtion COrrection (SLOMOCO) performs better than the volumetric methods and, moreover, accurately detects the motion of independent slices, in this case equivalent to the known injected motion. We demonstrate that SLOMOCO can model and correct for nearly all effects of motion in BOLD data. Also, none of the commonly used motion metrics was observed to robustly identify motion corrupted events, especially in the most realistic scenario of sudden head movement. For some popular metrics, performance was poor even when using the ideal known slice motion instead of volumetric parameters. This has negative implications for methods relying on these metrics, such as recently proposed motion correction methods such as data censoring and global signal regression. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:21 / 34
页数:14
相关论文
共 44 条
[1]
A quantitative comparison of motion detection algorithms in fMRI [J].
Ardekani, BA ;
Bachman, AH ;
Helpern, JA .
MAGNETIC RESONANCE IMAGING, 2001, 19 (07) :959-963
[2]
Isolating physiologic noise sources with independently determined spatial measures [J].
Beall, Erik B. ;
Lowe, Mark J. .
NEUROIMAGE, 2007, 37 (04) :1286-1300
[3]
The Effect of Forced-Exercise Therapy for Parkinson's Disease on Motor Cortex Functional Connectivity [J].
Beall, Erik B. ;
Lowe, Mark J. ;
Alberts, Jay L. ;
Frankemolle, Anneke M. M. ;
Thota, Anil K. ;
Shah, Chintan ;
Phillip, Michael D. .
BRAIN CONNECTIVITY, 2013, 3 (02) :190-198
[4]
The non-separability of physiologic noise in functional connectivity MRI with spatial ICA at 3T [J].
Beall, Erik B. ;
Lowe, Mark J. .
JOURNAL OF NEUROSCIENCE METHODS, 2010, 191 (02) :263-276
[5]
Adaptive cyclic physiologic noise modeling and correction in functional MRI [J].
Beall, Erik B. .
JOURNAL OF NEUROSCIENCE METHODS, 2010, 187 (02) :216-228
[6]
Bullmore ET, 1999, HUM BRAIN MAPP, V7, P38, DOI 10.1002/(SICI)1097-0193(1999)7:1<38::AID-HBM4>3.3.CO
[7]
2-H
[8]
Detection and elimination of motion artifacts by regeneration of k-space [J].
Bydder, M ;
Larkman, DJ ;
Hajnal, JV .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :677-686
[9]
Cox RW, 1999, MAGNET RESON MED, V42, P1014, DOI 10.1002/(SICI)1522-2594(199912)42:6<1014::AID-MRM4>3.0.CO
[10]
2-F