New methods for assessing cartilage contact stress after articular fracture

被引:35
作者
Brown, TD
Rudert, MJ
Grosland, NM
机构
[1] Univ Iowa, Orthopaed Biomech Lab, Dept Orthopaed Surg, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
关键词
D O I
10.1097/01.blo.0000132633.38338.8b
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Progress in reducing the incidence and severity of posttraumatic arthritis depends in part on avoiding deleterious stress levels at residual local incongruities. Systematic efforts to elucidate factors adversely influencing cartilage's mechanical environment in turn depend on the availability of suitable modalities to assess intraarticular contact stresses. This has been and remains a challenging biomechanical problem. Technologic approaches used in the past have included mathematical analyses and indwelling physical sensors, each with advantages and limitations. Two emerging, mutually complementary capabilities show promise of dramatically altering the state of the art in this important field. The first of these methodologies, voxel-based contact finite element analysis, provides accurate computational estimates of cartilage stress on a patient-specific basis, and does so while accommodating arbitrarily idiosyncratic patterns of local articular incongruity. The second methodology, instrumentational, involves transient pressure distribution recordings using specially designed piezoresistive array sensors. Operational considerations for both of these new assessment technologies are described, and promising directions for future development are outlined.
引用
收藏
页码:52 / 58
页数:7
相关论文
共 42 条
[1]
A PRESSURE DISTRIBUTION TRANSDUCER FOR INVITRO STATIC MEASUREMENTS IN SYNOVIAL JOINTS [J].
AHMED, AM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :309-314
[2]
Contact stress distributions in malreduced intraarticular distal radius fractures [J].
Anderson, DD ;
Bell, AL ;
Gaffney, MB ;
Imbriglia, JE .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (05) :331-337
[3]
Statically equivalent load and support conditions produce different hip joint contact pressures and periacetabular strains [J].
Bay, BK ;
Hamel, AJ ;
Olson, SA ;
Sharkey, NA .
JOURNAL OF BIOMECHANICS, 1997, 30 (02) :193-196
[4]
STRESS ON THE ARTICULAR SURFACE OF THE HIP-JOINT IN HEALTHY-ADULTS AND PERSONS WITH IDIOPATHIC OSTEOARTHROSIS OF THE HIP-JOINT [J].
BRINCKMANN, P ;
FROBIN, W ;
HIERHOLZER, E .
JOURNAL OF BIOMECHANICS, 1981, 14 (03) :149-156
[5]
CONTACT STRESS ABERRATIONS FOLLOWING IMPRECISE REDUCTION OF SIMPLE TIBIAL PLATEAU FRACTURES [J].
BROWN, TD ;
ANDERSON, DD ;
NEPOLA, JV ;
SINGERMAN, RJ ;
PEDERSEN, DR ;
BRAND, RA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (06) :851-862
[6]
A TECHNIQUE FOR MEASURING INSTANTANEOUS INVITRO CONTACT STRESS DISTRIBUTIONS IN ARTICULAR JOINTS [J].
BROWN, TD ;
SHAW, DT .
JOURNAL OF BIOMECHANICS, 1982, 15 (04) :329-&
[7]
A CONTACT-COUPLED FINITE-ELEMENT ANALYSIS OF THE NATURAL ADULT HIP [J].
BROWN, TD ;
DIGIOIA, AM .
JOURNAL OF BIOMECHANICS, 1984, 17 (06) :437-448
[8]
EFFECTS OF OSTEOCHONDRAL DEFECT SIZE ON CARTILAGE CONTACT STRESS [J].
BROWN, TD ;
POPE, DF ;
HALE, JE ;
BUCKWALTER, JA ;
BRAND, RA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (04) :559-567
[9]
AN ALGORITHM FOR APPROXIMATE CRINKLE ARTIFACT COMPENSATION IN PRESSURE-SENSITIVE FILM RECORDINGS [J].
CALDWELL, NJ ;
HALE, JE ;
RUDERT, MJ ;
BROWN, TD .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :1001-1009
[10]
RADIO TELEMETRY DEVICE FOR MONITORING CARTILAGE SURFACE PRESSURES IN HUMAN HIP [J].
CARLSON, CE ;
MANN, RW ;
HARRIS, WH .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1974, BM21 (04) :257-264