Microconcentric nebulizer for the coupling of micro liquid chromatography and capillary zone electrophoresis with inductively coupled plasma mass spectrometry

被引:43
作者
Tangen, A
Trones, R
Greibrokk, T
Lund, W
机构
[1] Department of Chemistry, University of Oslo, N-0315 Oslo
关键词
inductively coupled plasma mass spectrometry; direct injection nebulization; concentric nebulizer; speciation; micro liquid chromatography; capillary zone electrophoresis;
D O I
10.1039/a607623h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A concentric nebulizer designed to deliver less than 10 mu l min(-1) directly into an ICP-MS system is described, The influence of the liquid flow rate, the nebulizer gas flow rate and the distance from the nebulizer tip to the plasma was evaluated with regard to sensitivity and precision, The nebulizer was tested at liquid flow rates of 3-7 mu l min(-1). Samples of tetramethyllead and tetraethyllead dissolved in dimethylformamide were used for the evaluation of the nebulizer. The detection limit for Pb (m = 208) with a direct injection system was found to be 0.3 pg (S/N = 3) or 5 mu g l(-1), based on an injection volume of 60 nl, a liquid flow rate of 5 mu l min(-1) and a dwell time of 10 ms. The precision was found to be 1.9% (n = 10) based on peak area measurements, The responses of tetramethyllead and tetraethyllead were not significantly different (p = 0.05), The time needed for one determination was less than 15 s, owing to the quick rinse out of the nebulizer, The nebulizer can be used as part of a direct injection instrumental set-up. An application of the nebulizer to the coupling of packed capillary liquid chromatography with ICP-MS detection is demonstrated.
引用
收藏
页码:667 / 670
页数:4
相关论文
共 37 条
[1]   LEAD SPECIATION BY GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETECTION [J].
ALRASHDAN, A ;
VELA, NP ;
CARUSO, JA ;
HEITKEMPER, DT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (03) :551-555
[2]   LEAD SPECIATION BY HPLC-ICP-AES AND HPLC-ICP-MS [J].
ALRASHDAN, A ;
HEITKEMPER, D ;
CARUSO, JA .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (03) :98-102
[3]   CHARACTERIZATION AND OPTIMIZATION OF A DIRECT INJECTION NEBULIZER FOR INTRODUCTION OF ORGANIC-SOLVENTS AND VOLATILE ANALYTE SPECIES INTO AN INDUCTIVELY COUPLED PLASMA [J].
AVERY, TW ;
CHAKRABARTY, C ;
THOMPSON, JJ .
APPLIED SPECTROSCOPY, 1990, 44 (10) :1690-1698
[4]   SAMPLE INTRODUCTION AND ATOMIZATION OF VOLATILE ALKYLLEAD COMPOUNDS IN FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
BAGDI, G ;
LAKATOS, J ;
LAKATOS, I .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (05) :769-773
[5]   High-temperature hydraulic high-pressure nebulization: A recent nebulization principle for sample introduction [J].
Berndt, H ;
Yanez, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :703-712
[6]   SAMPLE INTRODUCTION TECHNIQUES FOR ATOMIC SPECTROSCOPY [J].
BROWNER, RF ;
BOORN, AW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :A875-+
[7]   SAMPLE INTRODUCTION - THE ACHILLES HEEL OF ATOMIC SPECTROSCOPY [J].
BROWNER, RF ;
BOORN, AW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :A786-&
[8]   ULTRASONIC NEBULIZATION OF LIQUID SAMPLES FOR ANALYTICAL INDUCTIVELY COUPLED PLASMA-ATOMIC SPECTROSCOPY - AN UPDATE [J].
FASSEL, VA ;
BEAR, BR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (10) :1089-1113
[9]   MONODISPERSE DRIED MICROPARTICULATE INJECTOR FOR ANALYTICAL INSTRUMENTATION [J].
FRENCH, JB ;
ETKIN, B ;
JONG, R .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :685-691
[10]  
HAJLBRAHIM SK, 1981, J LIQ CHROMATOGR, V4, P749