Pulse contour analysis versus thermodilution in cardiac surgery patients

被引:61
作者
Rauch, H [1 ]
Müller, M [1 ]
Fleischer, F [1 ]
Bauer, H [1 ]
Martin, E [1 ]
Böttiger, BW [1 ]
机构
[1] Univ Heidelberg, Dept Anesthesiol, D-69120 Heidelberg, Germany
关键词
cardiac output measurement; thermodilution; cardiac surgery;
D O I
10.1034/j.1399-6576.2002.460416.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Previous studies have demonstrated that there is a lack of agreement between intermittent cold bolus thermodilution (ICO) and a semicontinuous method with dilution of heat (CCO) in cardiac surgical patients following hypothermic extracorporeal circulation (HCPB). Therefore, the aim of the present study was to compare both ICO and CCO with continuous pulse contour analysis (PCCO): a method based on a fundamentally different principle of determining cardiac output (CC). Methods: A prospective criterion standard study of 25 cardiac surgery patients undergoing HCPB. Cardiac output was determined using the three methods (ICO, CCO, and PCCO) before and after HCPB up to 12h after arrival on the ICU. Bias and precision were evaluated. Results: A total of 380 triple determinations of CO could be analyzed. During the entire study period bias PCCO-ICO was -0.141*/min (precision 1.161*/min) bias CCO-ICO was -0.401*/min (precision 1.251*/min). Up to 45min after bypass PCCO agreed with ICO (bias -0.211*/min, precision 1.371*/min), while bias CCO-ICO was -1.301*/min (precision 1.451*/min). Conclusion: The agreement between PCCO and ICO in contrast to CCO in the first 45min after HCPB indicates that CCO underestimates CO during this-period. (C) Acta Anaesthesiologica Scandinavica 46 (2002).
引用
收藏
页码:424 / 429
页数:6
相关论文
共 27 条
[1]   ERRORS IN THERMODILUTION CARDIAC-OUTPUT MEASUREMENTS CAUSED BY RAPID PULMONARY-ARTERY TEMPERATURE DECREASES AFTER CARDIOPULMONARY BYPASS [J].
BAZARAL, MG ;
PETRE, J ;
NOVOA, R .
ANESTHESIOLOGY, 1992, 77 (01) :31-37
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Bottiger BW, 1996, INTENS CARE MED, V22, P312
[4]   CONTINUOUS VERSUS INTERMITTENT CARDIAC-OUTPUT MEASUREMENT IN CARDIAC SURGICAL PATIENTS UNDERGOING HYPOTHERMIC CARDIOPULMONARY BYPASS [J].
BOTTIGER, BW ;
RAUCH, H ;
BOHRER, H ;
MOTSCH, J ;
SODER, M ;
FLEISCHER, F ;
MARTIN, E .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (04) :405-411
[5]   Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation [J].
Bottiger, BW ;
Sinner, B ;
Motsch, J ;
Bach, A ;
Bauer, H ;
Martin, E .
ANAESTHESIA, 1997, 52 (03) :207-214
[6]   DOPPLER ULTRASONIC MEASUREMENT OF CARDIAC-OUTPUT - REPRODUCIBILITY AND VALIDATION [J].
COATS, AJS .
EUROPEAN HEART JOURNAL, 1990, 11 :49-61
[7]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[8]  
DARMON PL, 1994, ANESTHESIOLOGY, V80, P796, DOI 10.1097/00000542-199404000-00011
[9]   CLINICAL-EVALUATION OF IMPEDANCE CARDIOGRAPHY [J].
GOLDSTEIN, DS ;
CANNON, RO ;
ZIMLICHMAN, R ;
KEISER, HR .
CLINICAL PHYSIOLOGY, 1986, 6 (03) :235-251
[10]   INTRAOPERATIVE DETERMINATION OF CARDIAC-OUTPUT BY TRANSESOPHAGEAL CONTINUOUS WAVE DOPPLER [J].
GORCSAN, J ;
DIANA, P ;
BALL, BA ;
HATTLER, BG .
AMERICAN HEART JOURNAL, 1992, 123 (01) :171-176