Pressure pinched injection of nanolitre volumes in planar micro-analytical devices

被引:59
作者
Bai, XX [1 ]
Lee, HJ
Rossier, JS
Reymond, F
Schafer, H
Wossner, M
Girault, HH
机构
[1] Ecole Polytech Fed Lausanne, Lab Electrochim, CH-1015 Lausanne, Switzerland
[2] CIMO SA, DiagnoSwiss SA, Monthey, Switzerland
[3] Metrohm Lab, CH-9101 Herisau, Switzerland
来源
LAB ON A CHIP | 2002年 / 2卷 / 01期
关键词
D O I
10.1039/b109247b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method for injecting and driving fluids by means of a multi-port injection valve and syringe pumps in a micro-channel network is described. A structure composed of two micro-channels arranged as a cross is connected with capillary tubes to an external multi-port injection valve. The fluid flows are driven by pressure and the multi-port valve controls the direction of the flow within the different sections of the structure. The first position of the multi-port valve allows the preparation of the loading of the sample, which is pinched in the cross section of the two micro-channels. The second position allows the precise injection of nL volumes. No dead volume exists between injection and separation modes. The system can be used to prepare a sample plug by pressure in order to perform chromatography with a broad range of buffered or non-buffered solutions. Thanks to the insensitivity to the ionic strength of the sample, this injection method is useful for the injection of complex biological samples in microchip analysis. In order to demonstrate the feasibility of the method, different solutions of ionic or fluorescent molecules were injected and detected in a photoablated planar polymer device.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 30 条
[1]  
Alarie JP, 2001, ELECTROPHORESIS, V22, P312, DOI 10.1002/1522-2683(200101)22:2<312::AID-ELPS312>3.0.CO
[2]  
2-3
[3]  
Attiya S, 2001, ELECTROPHORESIS, V22, P318, DOI 10.1002/1522-2683(200101)22:2<318::AID-ELPS318>3.0.CO
[4]  
2-G
[5]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[6]  
2-M
[7]   Microfabricated centrifugal microfluidic systems: Characterization and multiple enzymatic assays [J].
Duffy, DC ;
Gillis, HL ;
Lin, J ;
Sheppard, NF ;
Kellogg, GJ .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4669-4678
[8]   Dispersion reduction in pressure driven flow through microetched channels [J].
Dutta, D ;
Leighton, DT .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :504-513
[9]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[10]   Dynamic DNA hybridization on a chip using paramagnetic beads [J].
Fan, ZH ;
Mangru, S ;
Granzow, R ;
Heaney, P ;
Ho, W ;
Dong, QP ;
Kumar, R .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4851-4859