摘要
Background: Inflammatory mediators can serve as biomarkers for the monitoring of the disease progression or prognosis in many conditions. In the present study we introduce an adaptation of a membrane-based technique in which the level of up to 40 cytokines and chemokines can be determined in both human and rodent blood in a semi-quantitative way. The planar assay was modified using the LI-COR (R) detection system (fluorescence based) rather than chemiluminescence and semi-quantitative outcomes were achieved by normalizing the outcomes using the automated exposure settings of the Odyssey readout device. The results were compared to the gold standard assay, namely ELISA. Results: The improved planar assay allowed the detection of a considerably higher number of analytes (n = 30 and n = 5 for fluorescent and chemiluminescent detection, respectively). The improved planar method showed high sensitivity up to 17 pg/ml and a linear correlation of the normalized fluorescence intensity with the results from the ELISA (r = 0.91). Conclusions: The results show that the membrane-based technique is a semi-quantitative assay that correlates satisfactorily to the gold standard when enhanced by the use of fluorescence and subsequent semi-quantitative analysis. This promising technique can be used to investigate inflammatory profiles in multiple conditions, particularly in studies with constraints in sample sizes and/or budget.
引用
收藏
页数:8
相关论文
共 13 条
[1]
Novel biomarkers in chronic heart failure [J].
Ahmad, Tariq ;
Fiuzat, Mona ;
Felker, G. Michael ;
O'Connor, Christopher .
NATURE REVIEWS CARDIOLOGY, 2012, 9 (06) :347-359
[2]
Biomarkers in heart failure [J].
Braunwald, Eugene .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (20) :2148-2159
[3]
Systematic Characterization of Myocardial Inflammation, Repair, and Remodeling in a Mouse Model of Reperfused Myocardial Infarction [J].
Christia, Panagiota ;
Bujak, Marcin ;
Gonzalez-Quesada, Carlos ;
Chen, Wei ;
Dobaczewski, Marcin ;
Reddy, Anilkumar ;
Frangogiannis, Nikolaos G. .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2013, 61 (08) :555-570
[4]
The Fire Within: Cardiac Inflammatory Signaling in Health and Disease [J].
Coggins, Matthew ;
Rosenzweig, Anthony .
CIRCULATION RESEARCH, 2012, 110 (01) :116-125
[5]
Inflammation in viral myocarditis: friend or foe? [J].
Corsten, Maarten F. ;
Schroen, Blanche ;
Heymans, Stephane .
TRENDS IN MOLECULAR MEDICINE, 2012, 18 (07) :426-437
[6]
Haab Brian B, 2004, Methods Mol Biol, V264, P33
[7]
Biochemical markers of neonatal sepsis [J].
Lam, Hugh S. ;
Ng, Pak C. .
PATHOLOGY, 2008, 40 (02) :141-148
[8]
ELISA and multiplex technologies for cytokine measurement in inflammation and aging research [J].
Leng, Sean X. ;
McElhaney, Janet E. ;
Walston, Jeremy D. ;
Xie, Dongxu ;
Fedarko, Neal S. ;
Kuchel, George A. .
JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2008, 63 (08) :879-884
[9]
Enzyme Immunoassay (EIA)/Enzyme-Linked Immunosorbent Assay (ELISA) [J].
Lequin, RM .
CLINICAL CHEMISTRY, 2005, 51 (12) :2415-2418
[10]
Multiplexed analysis of biomarkers related to obesity and the metabolic syndrome in human plasma, using the luminex-100 system [J].
Liu, MY ;
Xydakis, AM ;
Hoogeveen, RC ;
Jones, PH ;
Smith, EOB ;
Nelson, KW ;
Ballantyne, CM .
CLINICAL CHEMISTRY, 2005, 51 (07) :1102-1109