摘要
Polyaniline (PANI) uricase biosensor prepared with template process is reported first in this paper. The fabrication process is as follows. Firstly, a PANI-uricase electrode is obtained using one-step process. Secondly, the electrode is hydrolyzed in 6.0 mot/dm(3) hydrochloric acid solution to remove the uricase that may be affected by aniline monomer from PANI film. Finally, active uricase is immobilized into the PANI film based on the principle of the doping and undoping of the conducting polymer and a PANI-uricase biosensor is obtained. Some factors that affect response current are studied, such as temperature, pH, potential and substrate concentration. The determination of biosensors indicates that the response cur-rent of the biosensor prepared by template process decreases only by about 18% for 60 days, but that prepared by two-step process decreases by approximately 39% for 40 h. The uricase in PANI-uricase biosensor prepared by template process mainly interacts with the nitrogen linked to the quinoid ring. The biosensor is characterized with FTIR, UV-Vis and SEM for the first time. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1635 / 1640
页数:6
相关论文
共 21 条
[1]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[2]   The use of the antimony-antimonous oxide electrode in the determination of the concentration of hydrogen ions and in potentiometric Titrations the Prideaux-Ward universal buffer mixture [J].
Britton, HTS ;
Robinson, RA .
JOURNAL OF THE CHEMICAL SOCIETY, 1931, :458-473
[3]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[4]  
DUPOET PD, 1990, ANAL CHIM ACTA, V235, P255
[5]   ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS [J].
FOULDS, NC ;
LOWE, CR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1259-1264
[6]   Application of conducting polymers to biosensors [J].
Gerard, M ;
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) :345-359
[7]   Effect of alpha,alpha'-bipyridine on activity of the polyaniline uricase electrode [J].
Kan, JQ ;
Zhou, F ;
Mu, SL ;
Shi, YJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 30 (01) :7-10
[8]  
Kan JQ, 1997, SYNTHETIC MET, V87, P205, DOI 10.1016/S0379-6779(97)80110-5
[9]   Determination of uremic toxins in biofluids: creatinine, creatine, uric acid and xanthines [J].
Kochansky, CJ ;
Strein, TG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 747 (1-2) :217-227
[10]   POLYANILINE - INTERCONVERSION OF METALLIC AND INSULATING FORMS [J].
MACDIARMID, AG ;
CHIANG, JC ;
HALPERN, M ;
HUANG, WS ;
MU, SL ;
SOMASIRI, NLD ;
WU, WQ ;
YANIGER, SI .
MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1985, 121 (1-4) :173-180