Solid sample graphite furnace atomic absorption spectroscopy for supporting arsenic determination in sediments following a sequential extraction procedure

被引:32
作者
Sahuquillo, A
Rauret, G
Rehnert, A
Muntau, H
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Environm, I-21020 Ispra, Italy
[2] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
graphite furnace atomic absorption spectroscopy solid sampling; arsenic determination; sediments; extraction procedures;
D O I
10.1016/S0003-2670(02)01354-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid sample graphite furnace atomic absorption spectroscopy (SS-GFAAS) has been proposed since its appearance as a good alternative to wet methods of analysis in many matrices. Here, we examine the use of SS-GFAAS for total and leachable arsenic determination in sediments from distinct origins. Our direct analysis of seven selected sediments was not always free of spectral matrix interference, but the spectroscopic technique gave very good results for (a) direct arsenic measurement in solid residues from a range of leaching processes, (b) total arsenic determination (HNO3 leaching test) and (c) the evaluation of its potential remobilisation (modified BCR three-step sequential extraction scheme). For the optimised instrumental conditions, the analysis limit was 0.44 mg kg(-1) and long-term reproducibility was between 10-15%. The sum of leachable arsenic in HNO3 65%, and the residual fraction, gave recoveries from 72 to 118% of total arsenic content. These results are a good alternative to other cumbersome wet methods involving HE (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:15 / 24
页数:10
相关论文
共 24 条
[1]  
[Anonymous], 1994, US EPA method 3051
[2]  
[Anonymous], 1995, 11466 ISO
[3]  
BAUDO R, 1998, ACQUA ARIA, V4, P109
[4]   Direct determination of metals in solid samples by graphite-furnace atomic absorption spectrometry: Does sample mass influence the analytical results? [J].
Belarra, MA ;
Crespo, C ;
Martinez-Garbayo, MP ;
Castillo, JR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (12) :1855-1860
[5]  
BROWN AA, 1987, FRESEN Z ANAL CHEM, V328, P354
[6]   Nomenclature in evaluation of analytical methods including detection and quantification capabilities (IUPAC Recommendations 1995) [J].
Currie, LA .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :105-126
[7]   METAL SPECIATION-GENERAL CONCEPTS AND APPLICATIONS [J].
FORSTNER, U .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 51 (1-4) :5-23
[8]  
GLEYZES C, 2002, METHODOLOGIES SOIL S, pCH4
[9]  
GOMEZARIZA JL, 2000, SCI TOTAL ENVIRON, V246, P271
[10]   Validation of an arsenic sequential extraction method for evaluating mobility in sediments [J].
Keon, NE ;
Swartz, CH ;
Brabander, DJ ;
Harvey, CF ;
Hemond, HF .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (13) :2778-2784