Axial inductively coupled plasma time-of-flight mass spectrometry using direct liquid sample introduction

被引:21
作者
Westphal, CS
McLean, JA
Acon, BW
Allen, LA
Montaser, A [1 ]
机构
[1] George Washington Univ, Dept Chem, Washington, DC 20052 USA
[2] LECO Corp, St Joseph, MI 49085 USA
关键词
D O I
10.1039/b200771c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report is concerned with the first investigation of a direct injection high efficiency nebulizer (DIHEN) as a microliter-solution introduction system for axial inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS). The effect of rf generator frequency on analytical performance indices is investigated at both 27 and 40 MHz at operating conditions suitable for the DIHEN: a solution uptake rate of 100 muL min(-1), nebulizer gas flow rate of 0.2 L min(-1), and rf power from 800 to 1700 W. Four observations indicate an increased secondary discharge at 27 MHz compared to 40 MHz for the DIHEN compared to conventional solution introduction: (1) higher background count rates, (2) faster and wider ion deflection pulse times, (3) increased doubly-to-singly charged ion ratios (Ba2+/Ba+ = 0.03 vs. 0.02), and (4) reduced oxide-to-metal ion ratios (CeO+/Ce+ = 8.5 vs. 51) at 27 MHz in comparison with 40 MHz. Analytical figures of merit achieved, including detection limits, sensitivity, and precision using DIHEN-ICP-TOFMS are superior in both normal and cool plasma conditions to those obtained with a conventional nebulizer-spray chamber arrangement operated at a solution uptake rate of 1 mL min(-1). For example, typical precision (percent relative standard deviation, %RSD) for the DIHEN at 27 MHz is less than 0.6% for an integration time of 10 s. The signal intensity is nearly a factor of 2 higher with the DIHEN compared to the conventional nebulizer-spray chamber arrangement. Isotope ratio precision acquired by the DIHEN-ICP-TOFMS system closely approximates values predicted by Poisson counting statistics for both steady-state and transient signals. Finally, fast transient analysis (ca. 12.75 ms) is demonstrated for Sn and Cr isotopes in human lung fibroblast cells.
引用
收藏
页码:669 / 675
页数:7
相关论文
共 60 条
[1]   A large bore-direct injection high efficiency nebulizer for inductively coupled plasma spectrometry [J].
Acon, BW ;
McLean, JA ;
Montaser, A .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1885-1893
[2]   A direct injection high efficiency nebulizer interface for microbore high-performance liquid chromatography-inductively coupled plasma mass spectrometry [J].
Acon, BW ;
McLean, JA ;
Montaser, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (08) :852-857
[3]  
Allen L, 1998, PHYS STATUS SOLIDI A, V167, P357, DOI 10.1002/(SICI)1521-396X(199806)167:2<357::AID-PSSA357>3.0.CO
[4]  
2-A
[5]   Spatial location of the space charge effect in individual ion clouds using monodisperse dried microparticulate injection with a twin quadrupole inductively coupled plasma mass spectrometer [J].
Allen, LA ;
Leach, JJ ;
Houk, RS .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2384-2391
[6]   Precise measurement of ion ratios in solid samples using laser ablation with a twin quadrupole inductively coupled plasma mass spectrometer [J].
Allen, LA ;
Leach, JJ ;
Pang, HM ;
Houk, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) :171-176
[7]   SIMULTANEOUS MEASUREMENT OF ISOTOPE RATIOS IN SOLIDS BY LASER-ABLATION WITH A TWIN QUADRUPOLE INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETER [J].
ALLEN, LA ;
PANG, HM ;
WARREN, AR ;
HOUK, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (03) :267-271
[8]  
[Anonymous], 1990, IARC MON EV CARC RIS
[9]   Evaluation of the accuracy of the determination of lead isotope ratios in wine by ICP MS using quadrupole, multicollector magnetic sector and time-of-flight analyzers [J].
Barbaste, M ;
Halicz, L ;
Galy, A ;
Medina, B ;
Emteborg, H ;
Adams, FC ;
Lobinski, R .
TALANTA, 2001, 54 (02) :307-317
[10]   ION-TRAP MASS-SPECTROMETRY WITH AN INDUCTIVELY-COUPLED PLASMA SOURCE [J].
BARINAGA, CJ ;
KOPPENAAL, DW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (01) :71-76