Regional blood flow measurements from fluorescent microsphere images using an Imaging CryoMicrotome

被引:25
作者
Kelly, JJ [1 ]
Ewen, JR
Bernard, SL
Glenny, RW
Barlow, CH
机构
[1] Barlow Sci Inc, Olympia, WA 98502 USA
[2] Evergreen State Coll, Olympia, WA 98505 USA
[3] Univ Washington, Sch Med, Seattle, WA 98195 USA
关键词
D O I
10.1063/1.1150188
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An automated image acquisition and analysis system has been developed that rapidly determines regional blood flow by using the locations of fluorescent microspheres deposited in tissue. A motor-driven microtome removes sections of frozen tissues in steps variable between 10 and 100 mu m. Filtered light excites microsphere fluorescence from the exposed surface of the remaining tissue block. A charge coupled device camera records fluorescence images from the tissue block surface after removal of each slice. Approximately 450 images are analyzed from perfused rat hearts providing precise x, y, and z locations of about 10 000 microspheres. Image analysis of fluorescent microspheres is much faster and less labor intensive than traditional indirect microsphere-based flow measurements while providing higher quality data. (C) 2000 American Institute of Physics. [S0034-6748(00)01901-8].
引用
收藏
页码:228 / 234
页数:7
相关论文
共 10 条
[1]  
AN D, 1995, FLUORESCENT MICROSPH
[2]   INCREASED NUMBER OF MYOCARDIAL BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED MICROSPHERES [J].
BAER, RW ;
PAYNE, BD ;
VERRIER, ED ;
VLAHAKES, GJ ;
MOLODOWITCH, D ;
UHLIG, PN ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (03) :H418-H434
[3]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[4]   TOTAL AND REGIONAL CORONARY BLOOD FLOW MEASURED BY RADIOACTIVE MICROSPHERES IN CONSCIOUS AND ANESTHETIZED DOGS [J].
DOMENECH, RJ ;
HOFFMAN, JIE ;
NOBLE, MIM ;
SAUNDERS, KB ;
HENSON, JR ;
SUBIJANTO, S .
CIRCULATION RESEARCH, 1969, 25 (05) :581-+
[5]   VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION [J].
GLENNY, RW ;
BERNARD, S ;
BRINKLEY, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) :2585-2597
[6]   FLUORESCENT MICROSPHERES - A NEW TOOL FOR VISUALIZATION OF ISCHEMIC MYOCARDIUM IN RATS [J].
HALE, SL ;
VIVALDI, MT ;
KLONER, RA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (04) :H863-H868
[7]   BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES [J].
HEYMANN, MA ;
PAYNE, BD ;
HOFFMAN, JIE ;
RUDOLPH, AM .
PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) :55-79
[8]   A METHOD FOR USING MICROSPHERES TO MEASURE MUSCLE BLOOD-FLOW IN EXERCISING RATS [J].
LAUGHLIN, MH ;
ARMSTRONG, RB ;
WHITE, J ;
ROUK, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (06) :1629-1635
[9]   CIRCULATION OF FETUS IN UTERO - METHODS FOR STUDYING DISTRIBUTION OF BLOOD FLOW CARDIAC OUTPUT AND ORGAN BLOOD FLOW [J].
RUDOLPH, AM ;
HEYMANN, MA .
CIRCULATION RESEARCH, 1967, 21 (02) :163-&
[10]   FLUORESCENT MICROSPHERES TO MEASURE ORGAN PERFUSION - VALIDATION OF A SIMPLIFIED SAMPLE PROCESSING TECHNIQUE [J].
VANOOSTERHOUT, NFM ;
WILLIGERS, HMM ;
RENEMAN, RS ;
PRINZEN, FW .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (02) :H725-H733