Evaluation of the One-Step™ ELISA kit for the detection of buprenorphine in urine, blood, and hair specimens

被引:36
作者
Cirimele, V
Etienne, S
Villain, M
Ludes, B
Kintz, P
机构
[1] Inst Med Legale, Toxicol Lab, F-67085 Strasbourg, France
[2] Tox Chem Lab, F-67400 Illkirch Graffenstaden, France
关键词
buprenorphine; ELISA; biological fluids; hair; HPLC/MS;
D O I
10.1016/j.forsciint.2004.02.035
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
A solid-phase enzyme immunoassay involving microtiter plates was recently proposed by International Diagnostic Systems corporation (IDS) to screen for buprenorphine in human serum. The performance of the kit led us to investigate its applicability in other biological matrices such as urine or blood, and also hair specimens. Low concentrations of buprenorphine were detected with the ELISA test and confirmed by HPLC/MS (buprenorphine concentrations measured by HPLOMS: 0.3 ng/mL in urine, 0.2 ng/mL in blood, and 40 pg/mg in hair). The intra-assay precision values were 8.7% at 1 ng/mL of urine (n = 8), 11.5% at 2 ng/mL in serum (n = 8), and 11.5% at 250 pg/mg of hair (n = 8), respectively. The immunoassay had no cross-reactivity with dihydrocodeine, ethylmorphine, 6-monoacetylmorphine, pholcodine, propoxyphene, dextromoramide, dextrometorphan at 1 and 10 mg/L, or codeine, morphine, methadone, and its metabolite EDDP. A 1% cross-reactivity was measured for a norbuprenorphine concentration of 50 ng/mL. Finally, the immunoassay was validated by comparing authentic specimens results with those of a validated HPLC/MS method. From the 136 urine samples tested, 93 were positive (68.4%) after the ELISA screening test (cutoff: 0.5 ng/mL) and confirmed by HPLOMS (buprenorphine concentrations: 0.3-2036 ng/mL). From the 108 blood or serum samples screened, 27 were positive (25%) after the ELISA test with a cutoff value of 0.5 ng/mL (buprenorphine concentrations: 0.2-13.3 ng/mL). Eighteen hair specimens were positive (72%) after the screening (cutoff: 10 pg/mg) and confirmed by LC/MS (buprenorphine concentrations: 40-360 pg/mg). The ELISA method produced false positive results in less than 21% of the cases, but no false negative results were observed with the immunological test. Four potential adulterants (hypochloride 50 mL/L, sodium nitrite 50 g/L, liquid soap 50 mL/L, and sodium chloride 50 g/L) that were added to 10 positive urine specimens (buprenorphine concentrations in the range 5.3-15.6 ng/mL), did not cause a false negative response by the immunoassay. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:153 / 156
页数:4
相关论文
共 11 条
[1]  
[Anonymous], 1995, DISPOSITION TOXIC DR
[2]   Buprenorphine to norbuprenorphine ratio in human hair [J].
Cirimele, V ;
Kintz, P ;
Lohner, S ;
Ludes, B .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (06) :448-449
[3]   Enzyme immunoassay validation for the detection of buprenorphine in urine [J].
Cirimele, V ;
Kintz, P ;
Lohner, S ;
Ludes, B .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2003, 27 (02) :103-105
[4]  
Cirimele V, 2002, FORENSIC SCI MED, P89
[5]  
DEBRABANDERE L, 1992, J FORENSIC SCI, V37, P82
[6]   SENSITIVE SCREENING METHOD FOR BUPRENORPHINE IN URINE [J].
HACKETT, LP ;
DUSCI, LJ ;
ILETT, KF ;
SEOW, SSW ;
QUIGLEY, AJ .
JOURNAL OF CHROMATOGRAPHY, 1986, 374 (02) :400-404
[7]   Deaths involving buprenorphine: a compendium of French cases [J].
Kintz, P .
FORENSIC SCIENCE INTERNATIONAL, 2001, 121 (1-2) :65-69
[8]   COLUMN-SWITCHING SOLID-PHASE TRACE-ENRICHMENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR MEASUREMENT OF BUPRENORPHINE AND NORBUPRENORPHINE IN HUMAN PLASMA AND URINE BY ELECTROCHEMICAL DETECTION [J].
SCHLEYER, E ;
LOHMANN, R ;
ROLF, C ;
GRALOW, A ;
KAUFMANN, CC ;
UNTERHALT, M ;
HIDDEMANN, W .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 614 (02) :275-283
[9]   THE MU-PROPERTIES, KAPPA-PROPERTIES AND DELTA-PROPERTIES OF VARIOUS OPIOID AGONISTS [J].
TAKEMORI, AE ;
IKEDA, M ;
PORTOGHESE, PS .
EUROPEAN JOURNAL OF PHARMACOLOGY, 1986, 123 (03) :357-361
[10]   Buprenorphine-related deaths among drug addicts in France: A report on 20 fatalities [J].
Tracqui, A ;
Kintz, P ;
Ludes, B .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1998, 22 (06) :430-434