Hyphenation of multi-dimensional chromatography and mass spectrometry for the at-line-analysis of the integrity of recombinant protein drugs

被引:13
作者
Canarelli, S [1 ]
Fisch, I [1 ]
Freitag, R [1 ]
机构
[1] Swiss Fed Inst Technol, Ctr Biotechnol, Lab Chem Biotechnol, CH-1015 Lausanne, Ecublens, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 775卷 / 01期
关键词
recombinant protein drugs;
D O I
10.1016/S1570-0232(02)00286-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A robust tool is proposed for the rapid at-line verification of the identity and integrity of (recombinant) proteins, namely the hyphenation of multidimensional chromatography and mass spectrometry (MS). A recombinant human antibody produced in Chinese hamster ovary cells is taken as pertinent example. The recombinant human antibody is first captured from the production environment by affinity chromatography (rProtein A, isolation/concentration of the target molecule) and automatically transferred to an enzyme reactor (immobilized trypsin column) for digestion, thereby yielding different peptides corresponding to the protein sequence. The peptides are then separated on a reversed-phase column before being analyzed and identified by MS. This step does not require a fine resolution since the mass spectrometer can identify a variety of substances at the same time, The results are then analyzed in silico with suitable bio-informatic tools. When the gene sequence of the protein product is known. proteolytic cleavages can be predicted and the exact mass and hence the amino acid sequence of each peptide can thereby be deduced. Fitting experimental data and reference peptide sequences then provides important information about the integrity of the protein and more particularly about its sequence. In our case, the integrity of 45% of the light and 75% of the heavy chain sequences of the antibody could be verified within minutes. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:27 / 35
页数:9
相关论文
共 17 条
[1]   Isolation of the components of a complex mixture by means of column switching for their enhanced detection by mass spectrometry [J].
Allen, JR ;
Williams, JD ;
Burinsky, DJ ;
Cole, SR .
JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) :209-219
[2]  
[Anonymous], 2000, INT C HARM TECHN REQ
[3]   Combination of capillary electrophoresis and matrix-assisted laser desorption ionization mass spectrometry for glycosylation analysis of a human monoclonal anti-Rhesus(D) antibody [J].
Bihoreau, N ;
Ramon, C ;
Lazard, M ;
Schmitter, JM .
JOURNAL OF CHROMATOGRAPHY B, 1997, 697 (1-2) :123-133
[4]  
Blackburn RK, 1997, J AM SOC MASS SPECTR, V8, P483
[5]   On-line microdialysis of proteins with high-salt buffers for direct coupling of electrospray ionization mass spectrometry and liquid chromatography [J].
Canarelli, S ;
Fisch, I ;
Freitag, R .
JOURNAL OF CHROMATOGRAPHY A, 2002, 948 (1-2) :139-149
[6]  
Fischer R, 1999, BIOTECHNOL APPL BIOC, V30, P109
[7]   Comparison of different types of ceramic hydroxyapatite for the chromatographic separation of plasmid DNA and a recombinant anti-Rhesus D antibody [J].
Giovannini, R ;
Freitag, R .
BIOSEPARATION, 2000, 9 (06) :359-368
[8]   Isolation of a recombinant antibody from cell culture supernatant: Continuous annular versus batch and expanded-bed chromatography [J].
Giovannini, R ;
Freitag, R .
BIOTECHNOLOGY AND BIOENGINEERING, 2001, 73 (06) :522-529
[9]   On-line coupling of micro-enzyme reactor with micro-membrane chromatography for protein digestion, peptide separation, and protein identification using electrospray ionization mass spectrometry [J].
Jiang, Y ;
Lee, CS .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :315-322
[10]   Mass determination of oligosaccharides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry following HPLC, assisted by on-line desalting and automated sample handling [J].
Kabel, MA ;
Schols, HA ;
Voragen, AGJ .
CARBOHYDRATE POLYMERS, 2001, 44 (02) :161-165