Application of stir bar sorptive extraction to the determination of polycyclic aromatic hydrocarbons in aqueous samples

被引:122
作者
Kolahgar, B [1 ]
Hoffmann, A [1 ]
Heiden, AC [1 ]
机构
[1] Gerstel GMBH & Co KG, D-45473 Mulheim, Germany
关键词
stir bar sorptive extraction; extraction methods; water analysis; polycyclic aromatic hydrocarbons;
D O I
10.1016/S0021-9673(02)00361-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The technique of stir bar sorptive extraction is used for the determination of polycyclic aromatic hydrocarbons (PAH) in aqueous samples. The PAHs are extracted with 10-mm stir bars (Gerstel Twister) coated with 0.5 mm polydimethylsiloxane and analyzed with a gas chromatography-mass spectrometry system. The influence of methanol and hyamine addition to the samples for preventing wall effects is investigated at 100 ng/l. The results indicate improved sensitivity using hyamine addition to the samples. The optimal extraction time was found to be between 3 and 4 h. The reproducibility of the method, as determined by nine replicate measurements, is between 5 and 15% at 10 ng/l and between 3 and 9% at 50 ng/l. Carry-over, which was evaluated at 500 ng/l by desorbing the same Twister three times, seems to be negligible for most of the compounds. In worst cases, carry-over of up to 7% was found for indeno[1,2,3]pyrene, dibenz[a,h]anthracene, and benzo[g,h,i]perylene. The technique shows excellent linearities for 5 point calibrations. Detection limits are between 0.1 and 2 ng/l. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:225 / 230
页数:6
相关论文
共 13 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[3]  
2-4
[4]   DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN SURFACE-WATER BY COLUMN LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION, USING ONLINE MICELLE-MEDIATED SAMPLE PREPARATION [J].
BROUWER, ER ;
HERMANS, ANJ ;
LINGEMAN, H ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :45-57
[5]   Determination and stability of pesticides in freeze-dried water samples by automated on-line solid-phase extraction followed by liquid chromatography with diode-array detection [J].
Ferrer, I ;
Barcelo, D .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (01) :93-99
[6]  
Heberer T, 1995, IDENTIFIZIERUNG QUAN
[7]  
HEIDEN AC, 2001, COMPARISON SENSITIVI
[8]  
KICINSKI HG, 1993, GIT FACHZ LAB, V11, P999
[9]   On-line combination of aqueous-sample preparation and capillary gas chromatography [J].
Louter, AJH ;
Vreuls, JJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :391-426
[10]  
MORABITO PL, 1993, HRC-J HIGH RES CHROM, V16, P90, DOI 10.1002/jhrc.1240160205