Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters

被引:85
作者
Kalra, MK
Maher, MM
Blake, MA
Lucey, BC
Karau, K
Toth, TL
Avinash, G
Halpern, EF
Saini, S
机构
[1] Massachusetts Gen Hosp, Div Abdominal Imaging & Intervent, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] GE Med Syst, Waukesha, WI USA
关键词
D O I
10.1148/radiol.2323031563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To assess the effect of noise reduction filters on detection and characterization of lesions on low-radiation-close abdominal computed tomographic (CT) images. MATERIALS AND METHODS: Low-dose CT images of abdominal lesions in 19 consecutive patients (11 women, eight men; age range, 32-78 years) were obtained at reduced tube currents (120-144 mAs). These baseline low-dose CT images were postprocessed with six noise reduction filters; the resulting postprocessed images were then randomly assorted with baseline images. Three radiologists performed independent evaluation of randomized images for presence, number, margins, attenuation, conspicuity, calcification, and enhancement of lesions, as well as image noise. Side-by-side comparison of baseline images with postprocessed images was performed by using a five-point scale for assessing lesion conspicuity and margins, image noise, beam hardening, and diagnostic acceptability. Quantitative noise and contrast-to-noise ratio were obtained for all liver lesions. Statistical analysis was performed by using the Wilcoxon signed rank test, Student t test, and kappa test of agreement. RESULTS: Significant reduction of noise was observed in images postprocessed with filter F compared with the noise in baseline nonfiltered images (P = 004). Although the number of lesions seen on baseline images and that seen on postprocessed images were identical, lesions were less conspicuous on postprocessed images than on baseline images. A decrease in quantitative image noise and contrast-to-noise ratio for liver lesions was noted with all noise reduction filters. There was good interobserver agreement (kappa = 0.7). CONCLUSION: Although the use of currently available noise reduction filters improves image noise and ameliorates beam-hardening artifacts at low-dose CT, such filters are limited by a compromise in lesion conspicuity and appearance in comparison with lesion conspicuity and appearance on baseline low-dose CT images. (C) RSNA 2004.
引用
收藏
页码:791 / 797
页数:7
相关论文
共 17 条
[1]
OPTIMAL PROCESSING OF COMPUTED TOMOGRAPHY IMAGES USING EXPERIMENTALLY MEASURED NOISE PROPERTIES [J].
ALVAREZ, RE ;
STONESTROM, JP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (01) :77-84
[2]
Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[3]
Pediatric CT: practical approach to diminish the radiation dose [J].
Frush, DP .
PEDIATRIC RADIOLOGY, 2002, 32 (10) :714-717
[4]
Improved pediatric multidetector body CT using a size-based color-coded format [J].
Frush, DP ;
Soden, B ;
Frush, KS ;
Lowry, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) :721-726
[5]
Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[7]
Further reduction of radiation dose in helical CT for lung cancer screening using small tube current and a newly designed filter [J].
Itoh, S ;
Koyama, S ;
Ikeda, M ;
Ozaki, M ;
Sawaki, A ;
Iwano, S ;
Ishigaki, T .
JOURNAL OF THORACIC IMAGING, 2001, 16 (02) :81-88
[8]
Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study [J].
Kalra, MK ;
Wittram, C ;
Maher, MM ;
Sharma, A ;
Avinash, GB ;
Karau, K ;
Toth, TL ;
Halpern, E ;
Saini, S ;
Shepard, JA .
RADIOLOGY, 2003, 228 (01) :257-264
[9]
Low-dose CT of the abdomen: Evaluation of image improvement with use of noise reduction filters - Pilot study [J].
Kalra, MK ;
Maher, MM ;
Sahani, DV ;
Blake, MA ;
Hahn, PF ;
Avinash, GB ;
Toth, TL ;
Halpern, E ;
Saini, S .
RADIOLOGY, 2003, 228 (01) :251-256
[10]
Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: Effect on image quality [J].
Kalra, MK ;
Prasad, S ;
Saini, S ;
Blake, MA ;
Varghese, J ;
Halpern, EF ;
Thrall, JH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) :1101-1106