Device closure of iatrogenic membranous ventricular septal defects after prosthetic aortic valve replacement using the amplatzer membranous ventricular septal defect occluder

被引:18
作者
Holzer, R
Latson, L
Hijazi, ZM
机构
[1] Univ Chicago, Childrens Hosp, Dept Pediat, Cardiol Sect, Chicago, IL 60637 USA
[2] Cleveland Clin, Dept Pediat Cardiol, Cleveland, OH 44106 USA
关键词
prosthetic aortic valve; ventricular septal defect; catheter intervention;
D O I
10.1002/ccd.20047
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Iatrogenic hemodynamically significant ventricular septal defects (VSDs) after aortic valve replacement are rare. The surgical risk to close such VSDs is substantial. Catheter closure has rarely been attempted because access to the left ventricle during cardiac catheterization in patients with a prosthetic aortic valve has been associated with a risk of catheter entrapment. We describe two cases of this rare entity after St. Jude and Medtronic valve replacement in which successful percutaneous closure of the iatrogenic VSDs was achieved using the Amplatzer membranous VSD occluder. Crossing the prosthetic valves with a delivery sheath and closure with the membranous VSD device was accomplished in both cases, (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:276 / 280
页数:5
相关论文
共 10 条
[1]   An unusual case of acquired ventricular septal defect as a complication of aortic valve endocarditis: Echocardiographic delineation of multiple subvalvular complications in one patient [J].
Ashmeik, K ;
Pai, RG .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (07) :693-695
[2]  
BACHA EA, IN PRESS J THORAC CA
[3]   GERBODE VENTRICULAR SEPTAL-DEFECT FOLLOWING ENDOCARDITIS [J].
BATTIN, M ;
FONG, LV ;
MONRO, JL .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1991, 5 (11) :613-614
[4]  
Dzwonczyk T, 1995, J Am Soc Echocardiogr, V8, P263, DOI 10.1016/S0894-7317(05)80036-7
[5]   Catheter closure of perimembranous ventricular septal defects using the new amplatzer membranous VSD occluder: Initial clinical experience [J].
Hijazi, ZM ;
Hakim, F ;
Abu Haweleh, A ;
Madani, A ;
Tarawna, W ;
Hiari, A ;
Cao, OL .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (04) :508-515
[6]  
Hijazi ZM, 2000, CATHETER CARDIO INTE, V49, P167, DOI 10.1002/(SICI)1522-726X(200002)49:2<167::AID-CCD11>3.0.CO
[7]  
2-S
[8]   DEATH DUE TO TRANSPROSTHETIC CATHETERIZATION OF A BJORK-SHILEY PROSTHESIS IN THE AORTIC POSITION [J].
HORSTKOTTE, D ;
JEHLE, J ;
LOOGEN, F .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (06) :566-567
[9]   RETROGRADE LEFT-VENTRICULAR CATHETERIZATION IN PATIENTS WITH AN AORTIC-VALVE PROSTHESIS [J].
KARSH, DL ;
MICHAELSON, SP ;
LANGOU, RA ;
COHEN, LS ;
WOLFSON, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (05) :893-896
[10]   CATHETER ENTRAPMENT IN A BJORK-SHILEY PROSTHESIS IN AORTIC POSITION [J].
KOBER, G ;
HILGERMANN, R .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1987, 13 (04) :262-265