Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax

被引:131
作者
Haage, P [1 ]
Schmitz-Rode, T [1 ]
Hübner, D [1 ]
Piroth, W [1 ]
Günther, RW [1 ]
机构
[1] Aachen Tech Univ, Dept Diagnost Radiol, D-52057 Aachen, Germany
关键词
D O I
10.2214/ajr.174.4.1741049
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our objective was to evaluate a combined method of contrast material bolus followed by saline solution flush for thoracic helical CT and statistical comparison with a uniphasic injection protocol. MATERIALS AND METHODS. Fifty patients underwent helical CT of the thorax using 60 mi of contrast material (370 mg I/ml) followed by flushing with 30 mi of physiologic saline solution. These 50 patients had been examined before using our previous protocol, 75 mi of the same contrast material without a subsequent saline solution. Mean attenuation values for both protocols were measured in the superior vena cava, the pulmonary trunk, and the ascending aorta. Image artifacts and mediastinal and hilar depiction were graded and compared. RESULTS. Mean attenuation values in the superior vena cava were considerably higher in the regimen without saline solution flush (459 ii versus 352 Il) and in the pulmonary trunk and the ascending aorta were almost identical for both protocols. Injection of saline solution diminished surrounding artifacts (p = 0.001). Grading results for the evaluation of mediastinal and hilar structures were not significantly different in the two protocols (p = 0.564). CONCLUSION. Injection of contrast material followed by a saline solution bolus using a double power injector when performing thoracic helical CT allows a 20% reduction of contrast material volume to 60 mi with a similar degree of enhancement. In addition, perivenous artifacts in the superior vena cava are significantly reduced.
引用
收藏
页码:1049 / 1053
页数:5
相关论文
共 12 条
[1]   PULMONARY NODULES - EFFECT OF INCREASED DATA SAMPLING ON DETECTION WITH SPIRAL CT AND CONFIDENCE IN DIAGNOSIS [J].
BUCKLEY, JA ;
SCOTT, WW ;
SIEGELMAN, SS ;
KUHLMAN, JE ;
URBAN, BA ;
BLUEMKE, DA ;
FISHMAN, EK .
RADIOLOGY, 1995, 196 (02) :395-400
[2]   Variability in the detection of enlarged mediastinal lymph nodes in staging lung cancer: A comparison of contrast-enhanced and unenhanced CT [J].
Cascade, PN ;
Gross, BH ;
Kazerooni, EA ;
Quint, LE ;
Francis, IR ;
Strawderman, M ;
Korobkin, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (04) :927-931
[3]   EXTRAVASATION OF NONIONIC RADIOLOGIC CONTRAST-MEDIA - EFFICACY OF CONSERVATIVE TREATMENT [J].
COHAN, RH ;
DUNNICK, NR ;
LEDER, RA ;
BAKER, ME .
RADIOLOGY, 1990, 176 (01) :65-67
[4]   SPIRAL CT OF THE THORAX WITH REDUCED VOLUME OF CONTRAST MATERIAL - A COMPARATIVE-STUDY [J].
COSTELLO, P ;
DUPUY, DE ;
ECKER, CP ;
TELLO, R .
RADIOLOGY, 1992, 183 (03) :663-666
[5]   THORACIC HELICAL CT [J].
COSTELLO, P .
RADIOGRAPHICS, 1994, 14 (04) :913-918
[6]   COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION [J].
CRAWFORD, CR ;
KING, KF .
MEDICAL PHYSICS, 1990, 17 (06) :967-982
[7]   SELECTIVE USE OF LOW-OSMOLAR CONTRAST-MEDIA [J].
DEBATIN, JF ;
COHAN, RH ;
LEDER, RA ;
ZAKRZEWSKI, CB ;
DUNNICK, NR .
INVESTIGATIVE RADIOLOGY, 1991, 26 (01) :17-21
[8]   Contrast for bolus injections in helical CT. [J].
Hopper, KD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) :715-715
[9]   Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector [J].
Hopper, KD ;
Mosher, TJ ;
Kasales, CJ ;
TenHave, TR ;
Tully, DA ;
Weaver, JS .
RADIOLOGY, 1997, 205 (01) :269-271
[10]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183