Predicting membrane oxygenator pressure drop using computational fluid dynamics

被引:45
作者
Gage, KL
Gartner, MJ
Burgreen, GW
Wagner, WR
机构
[1] Univ Pittsburgh, Dept Chem Engn, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15213 USA
关键词
membrane oxygenator; computational fluid dynamics; pressure drop; optimization; artificial lung;
D O I
10.1046/j.1525-1594.2002.07082.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Three-dimensional computational fluid dynamic (CFD) simulations of membrane oxygenators should allow prediction of spatially dependent variables and subsequent shape optimization. Fiber bed complexity and current computational limitations require the use of approximate models to predict fiber drag effects in complete device simulations. A membrane oxygenator was modified to allow pressure measurement along the fiber bundle in all cardinal axes. Experimental pressure drop information with water perfusion was used to calculate the permeability of the fiber bundle. A three-dimensional CFD model of a commercial membrane oxygenator was developed to predict pressure drops throughout the device. Darcy's Law was used to account for the viscous drag of the fibers and was incorporated as a momentum loss term in the conservation equations. Close agreement was shown between experimental and simulated pressure drops at lower flow rates, but the simulated pressure drops were lower than experimental results at higher flows. Alternate models of fiber drag effects and flow field visualization are suggested as means to potentially improve the accuracy of the flow simulation. Computational techniques coupled with experimental verification offer insight into model validity and show promise for the development of accurate three-dimensional simulations of membrane oxygenators.
引用
收藏
页码:600 / 607
页数:8
相关论文
共 16 条
[1]   Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics [J].
Apel, J ;
Paul, R ;
Klaus, S ;
Siess, T ;
Reul, H .
ARTIFICIAL ORGANS, 2001, 25 (05) :341-347
[2]  
Bird R.B., 2006, TRANSPORT PHENOMENA, Vsecond, DOI 10.1002/aic.690070245
[3]   3-DIMENSIONAL NUMERICAL PREDICTION OF STRESS LOADING OF BLOOD PARTICLES IN A CENTRIFUGAL PUMP [J].
BLUDSZUWEIT, C .
ARTIFICIAL ORGANS, 1995, 19 (07) :590-596
[4]   Computational fluid dynamics as a development tool for rotary blood pumps [J].
Burgreen, GW ;
Antaki, JF ;
Wu, ZJ ;
Holmes, AJ .
ARTIFICIAL ORGANS, 2001, 25 (05) :336-340
[5]   Hydrodynamic characteristics of artificial lungs [J].
Dierickx, PW ;
De Somer, F ;
De Wachter, DS ;
Van Nooten, G ;
Verdonck, PR .
ASAIO JOURNAL, 2000, 46 (05) :532-535
[6]   Blood flow around hollow fibers [J].
Dierickx, PWT ;
De Wachter, D ;
Verdonck, PR .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2000, 23 (09) :610-617
[7]  
*FLUENT INC, 1998, FLUENT 5 US GUID, V2, pCH8
[8]  
*FLUENT INC, 1998, FLUENT 5 US GUID, V1, pCH6
[9]   Modeling flow effects on thrombotic deposition in a membrane oxygenator [J].
Gartner, MJ ;
Wilhelm, CR ;
Gage, KL ;
Fabrizio, MC ;
Wagner, WR .
ARTIFICIAL ORGANS, 2000, 24 (01) :29-36
[10]  
Goodin Mark S., 1994, Perfusion, V9, P217, DOI 10.1177/026765919400900310