Autologous fibrin sealant (Vivostat®) for mesh fixation in laparoscopic transabdominal preperitoneal hernia repair

被引:8
作者
Schmidt, S. C. [1 ]
Langrehr, J. M. [1 ]
机构
[1] Univ Med Berlin, Virchow Clin, Dept Gen Visceral & Transplantat Surg, D-13353 Berlin, Germany
关键词
D O I
10.1055/s-2006-944609
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims: The use of fibrin glue derived from humans or animals has been reported as an alternative method of mesh fixation, instead of staples, in inguinal hernia repair. However, fibrin sealants involve the potential risks of virus transmission or immunological reactions to foreign proteins. This risk could be avoided by using autologous fibrin derived from the patient. A feasibility study on the use of autologous fibrin was therefore carried out in patients undergoing laparoscopic transabdominal inguinal hernia repair. Patients and methods: In a series of 10 patients undergoing laparoscopic transabdominal inguinal hernia repair, autologous fibrin was produced from 120 ml of the patient's blood during the hernia repair. The process took an average of 20 min. The peri-operative and postoperative results were compared with those in a control group of 20 patients in whom conventional fibrin was used. Results: Producing and applying the autologous fibrin was un-complicated. No differences in the outcome were observed between the two groups. One patient in the conventional fibrin group developed a seroma. None of the patients reported persistent pain. No recurrences were observed after a mean follow-up period of 9 months (range 6-12 months) in the conventional fibrin group and 7 months (range 6-8 months) in the autologous fibrin group. Conclusions: This feasibility study suggests that autologous fibrin sealant allowed adequate mesh fixation that did not differ from that in a control group in whom conventional fibrin glue was used. Autologous fibrin may be an interesting alternative for a variety of laparoscopic and endoscopic applications.
引用
收藏
页码:841 / 844
页数:4
相关论文
共 16 条
[1]   Comparison of endoscopic techniques vs Shouldice and other open nonmesh techniques for inguinal hernia repair - A meta-analysis of randomized controlled trials [J].
Bittner, R ;
Sauerland, S ;
Schmedt, CG .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2005, 19 (05) :605-615
[2]   Prospective randomized study of stapled versus unstapled mesh in a laparoscopic preperitoneal inguinal hernia repair [J].
Ferzli, GS ;
Frezza, EE ;
Pecoraro, AM ;
Ahern, KD .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1999, 188 (05) :461-465
[3]   Transmission of symptomatic parvovirus B19 infection by fibrin sealant used during surgery [J].
Hino, M ;
Ishiko, O ;
Honda, KI ;
Yamane, T ;
Ohta, K ;
Takubo, T ;
Tatsumi, N .
BRITISH JOURNAL OF HAEMATOLOGY, 2000, 108 (01) :194-195
[4]   Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair [J].
Katkhouda, N ;
Mavor, E ;
Friedlander, MH ;
Mason, RJ ;
Kiyabu, M ;
Grant, SW ;
Achanta, K ;
Kirkman, EL ;
Narayanan, K ;
Essani, R .
ANNALS OF SURGERY, 2001, 233 (01) :18-25
[5]   Vivostat system autologous fibrin sealant: Preliminary study in elective coronary bypass grafting [J].
Kjaergard, HK ;
Trumbull, HR .
ANNALS OF THORACIC SURGERY, 1998, 66 (02) :482-486
[6]  
Langrehr J M, 2005, Rozhl Chir, V84, P399
[7]   Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty - A randomized prospective trial [J].
Lau, H .
ANNALS OF SURGERY, 2005, 242 (05) :670-675
[8]   Fibrin glue for securing the mesh in laparoscopic totally extraperitoneal inguinal hernia repair [J].
Novik, B ;
Hagedorn, S ;
Mörk, UB ;
Dahlin, K ;
Skullman, S ;
Dalenbäck, J .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (03) :462-467
[9]  
Olmi Stefano, 2005, Chir Ital, V57, P753
[10]   Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat [J].
Petter-Puchner A.H. ;
Fortelny R. ;
Mittermayr R. ;
Öhlinger W. ;
Redl H. .
Hernia, 2005, 9 (4) :322-329