Sol-gel based surface modification of electrodes for electro analysis

被引:41
作者
Aurobind, S. V. [1 ]
Amirthalingam, K. P. [1 ]
Gomathi, H. [1 ]
机构
[1] Cent Electrochem Res Inst, Ctr Educ, Karaikkudi 630006, Tamil Nadu, India
关键词
sol-gel; pH sensor;
D O I
10.1016/j.cis.2006.04.001
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
in chemical analysis and electrochemical catalysis modified electrodes have been used in a wide range. In addition to the several methods of electrode modification reported in literature, the sol-gel route offers a possibility of preparing ceramic like films under rather mild conditions. This enhances the possibility of incorporation of temperature sensitive particles such as enzymes, microorganisms, proteins and several other biomolecules into such composite layers, resulting in very inert and stable matrices useful for analytical applications. The present paper, in addition to providing an overview of the various analytical applications of sol-gel processes, presents the fabrication and evaluation, of a novel sol-gel based potentiometric sensor for pH measurement. The performance characteristics of the sol-gel based pH sensor is evaluated using buffers in the pH range 2-10 prepared using standard buffer compositions reported in literature. The results show a linear correlation between negative logarithm of hydrogen ion concentration and measured millivolt response. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 21 条
[1]  
BRINKER J, 1989, SOL GEL SCI
[2]   Reagentless amperometric determination of hydrogen peroxide by silica sol-gel modified biosensor [J].
Chut, SL ;
Li, J ;
Tan, SN .
ANALYST, 1997, 122 (11) :1431-1434
[3]  
Klein L. C., 1994, Sol-Gel Optics: Procesing and Applications
[4]   Using sol-gel chemistry to synthesize a material with properties suited for chemical sensing - Development and implementation of a materials science experiment for the undergraduate curriculum [J].
Laughlin, JB ;
Sarquis, JL ;
Jones, VM ;
Cox, JA .
JOURNAL OF CHEMICAL EDUCATION, 2000, 77 (01) :77-79
[5]   ORGANICALLY MODIFIED SOL-GEL SENSORS [J].
LEV, O ;
TSIONSKY, M ;
RABINOVICH, L ;
GLEZER, V ;
SAMPATH, S ;
PANKRATOV, I ;
GUN, J .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :A22-A30
[6]   A cholesterol biosensor based on entrapment of cholesterol oxidase in a silicic sol-gel matrix at a Prussian blue modified electrode [J].
Li, JP ;
Peng, TZ ;
Peng, YQ .
ELECTROANALYSIS, 2003, 15 (12) :1031-1037
[7]  
MECARTNEY S, 1994, P MAT RES SOC
[8]  
Pandey PC, 1999, ELECTROANAL, V11, P59, DOI 10.1002/(SICI)1521-4109(199901)11:1<59::AID-ELAN59>3.0.CO
[9]  
2-P
[10]   Electrochemical behavior of graphite electrodes modified by spin-coating with sol-gel entrapped ionomers [J].
PetitDominguez, MD ;
Shen, H ;
Heineman, WR ;
Seliskar, CJ .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :703-710