A cholesterol biosensor based on entrapment of cholesterol oxidase in a silicic sol-gel matrix at a Prussian blue modified electrode

被引:101
作者
Li, JP
Peng, TZ
Peng, YQ
机构
[1] Zhejiang Univ, Dept Chem, Hangzhou 310028, Peoples R China
[2] Guilin Inst Technol, Dept Appl Chem, Guilin 541004, Peoples R China
[3] Zhejiang Univ, Dept Biol, Hangzhou 310028, Peoples R China
关键词
biosensor; cholesterol oxidase; Prussian blue; sol-gel; voltammetry; chronoamperometry;
D O I
10.1002/elan.200390124
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A cholesterol biosensors fabricated by immobilization of cholesterol oxidase (ChOx) in a layer of silicic sol-gel matrix on the top of a Prussian Blue-modified glassy carbon electrode was prepared. It is based on the detection of hydrogen peroxide produced by ChOx at - 0.05 V The half-lifetime of the biosensor is about 35 days. Cholesterol can be determined in the concentration range of 1 x 10(-6) - 8 x 10(-5) mol/L with a detection limit of 1.2 x 10(-7) mol/L. Normal interfering compounds, such as ascorbic acid and uric acid do not affect the determination. The high sensitivity and outstanding selectivity are attributed to the Prussian Blue film modified on the sensor.
引用
收藏
页码:1031 / 1037
页数:7
相关论文
共 42 条
[1]   Improvement of the analytical characteristics of an enzyme electrode for free and total cholesterol via laponite clay additives [J].
Besombes, JL ;
Cosnier, S ;
Labbe, P ;
Reverdy, G .
ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) :275-280
[2]   Improvement of poly(amphiphilic pyrrole) enzyme electrodes via the incorporation of synthetic laponite-clay-nanoparticles [J].
Besombes, JL ;
Cosnier, S ;
Labbe, P .
TALANTA, 1997, 44 (12) :2209-2215
[3]   THIN-FILM BIENZYME AMPEROMETRIC BIOSENSORS BASED ON POLYMERIC REDOX MEDIATORS WITH ELECTROSTATIC BIPOLAR PROTECTING LAYER [J].
BOGUSLAVSKY, L ;
KALASH, H ;
XU, Z ;
BECKLES, D ;
GENG, L ;
SKOTHEIM, T ;
LAURINAVICIUS, V ;
LEE, HS .
ANALYTICA CHIMICA ACTA, 1995, 311 (01) :15-21
[4]   An electrochemical multienzymatic biosensor for determination of cholesterol [J].
Bongiovanni, C ;
Ferri, T ;
Poscia, A ;
Varalli, M ;
Santucci, R ;
Desideri, A .
BIOELECTROCHEMISTRY, 2001, 54 (01) :17-22
[5]   Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane [J].
Brahim, S ;
Narinesingh, D ;
Guiseppi-Elie, A .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :27-36
[6]   Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode [J].
Charpentier, L ;
ElMurr, N .
ANALYTICA CHIMICA ACTA, 1995, 318 (01) :89-93
[7]   Sol-gels and electrochemistry: Research at the intersection [J].
Collinson, MM ;
Howells, AR .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :702A-709A
[8]   Sol-gel strategies for the preparation of selective materials for chemical analysis [J].
Collinson, MM .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1999, 29 (04) :289-311
[9]   SOL-GEL ENCAPSULATION METHODS FOR BIOSENSORS [J].
DAVE, BC ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :A1120-A1127
[10]   Evaluation of glucose biosensors based on Prussian Blue and lyophilised, crystalline and cross-linked glucose oxidases (CLEC®) [J].
de Mattos, IL ;
Lukachova, LV ;
Gorton, L ;
Laurell, T ;
Karyakin, AA .
TALANTA, 2001, 54 (05) :963-974