Comparative evaluation of eight commercial enzyme linked immunosorbent assays and 14 simple assays for detection of antibodies to HIV

被引:25
作者
Beelaert, G
Vercauteren, G
Fransen, K
Mangelschots, M
De Rooy, M
Garcia-Ribas, S
van der Groen, G
机构
[1] Inst Trop Med, Dept Microbiol, B-2000 Antwerp, Belgium
[2] WHO, Dept Blood Safety & Clin Technol, CH-1211 Geneva, Switzerland
关键词
HIV-1; HIV-2; ELISA; sensitivity; specificity; evaluation;
D O I
10.1016/S0166-0934(02)00102-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To evaluate the performance of 22 assays for the detection of antibodies to HIV. Twenty-two assays for the combined detection of antibodies to HIV-1 and HIV-2, were evaluated on the same panel of serum specimens of diverse origin. Eight of the assays were ELISAs and the remaining 14 were simple, assays read visually. The specimen panel consisted of anti-HIV positive and negative samples from Africa (n = 192), Europe (n = 206), Asia (n = 99) and Latin America (n = 98). In addition to estimations of sensitivity and specificity, the assays were assessed, using a novel scoring system, for their ease of performance and for their suitability for use in small laboratories and clinics. The sensitivities of the assays in terms of seroconversion were assessed using series of specimens collected from nine individuals undergoing seroconversion. Eight ELISAs and eight of 14 simple assays had sensitivities and specificities of > 99 and 95%, respectively. The results of these evaluations will be of assistance to those responsible for the selection of appropriate anti-HIV assays according to laboratory circumstances, the purpose of the testing and the population being tested. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:197 / 206
页数:10
相关论文
共 11 条
[1]  
APETREI C, 1996, AIDS, V10, P57
[2]   Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test [J].
Brust, S ;
Duttmann, H ;
Feldner, J ;
Gürtler, L ;
Thorstensson, R ;
Simon, F .
JOURNAL OF VIROLOGICAL METHODS, 2000, 90 (02) :153-165
[3]   EVALUATION OF ENZYME-LINKED IMMUNOSORBENT ASSAYS - A METHOD OF DATA-ANALYSIS [J].
CROFTS, N ;
MASKILL, W ;
GUST, ID .
JOURNAL OF VIROLOGICAL METHODS, 1988, 22 (01) :51-59
[4]  
JANSON J, 1995, P 8 INT S WOOD PULP, V1, P451
[5]   AN EVALUATION OF COMPETITIVE AND 2ND GENERATION ELISA SCREENING-TESTS FOR ANTIBODY TO HIV [J].
MASKILL, WJ ;
CROFTS, N ;
WALDMAN, E ;
HEALEY, DS ;
HOWARD, TS ;
SILVESTER, C ;
GUST, ID .
JOURNAL OF VIROLOGICAL METHODS, 1988, 22 (01) :61-73
[6]   Evaluation of 14 commercial HIV-1/HIV-2 antibody assays using serum panels of different geographical origin and clinical stage including a unique seroconversion panel [J].
Thorstensson, R ;
Andersson, S ;
Lindbäck, S ;
Dias, F ;
Mhalu, F ;
Gaines, H ;
Biberfeld, G .
JOURNAL OF VIROLOGICAL METHODS, 1998, 70 (02) :139-151
[7]   Improved performance of seroconversion with a 4th generation HIV Antigen/Antibody assay [J].
van Binsbergen, J ;
Siebelink, A ;
Jacobs, A ;
Keur, W ;
Bruynis, F ;
van de Graaf, M ;
van der Heijden, J ;
Kambel, D ;
Toonen, J .
JOURNAL OF VIROLOGICAL METHODS, 1999, 82 (01) :77-84
[8]   Reduction of diagnostic window by new fourth-generation human immunodeficiency virus screening assays [J].
Weber, B ;
Fall, EHM ;
Berger, A ;
Doerr, HW .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (08) :2235-2239
[9]  
*WHO UNAIDS, 1998, REV REC SEL US HIV A
[10]  
*WHO UNAIDS, 1998, 910 WHO UNAIDS