Fast and type-specific analysis of herpes simplex virus types 1 and 2 by rapid PCR and fluorescence melting-curve-analysis

被引:41
作者
Schalasta, G
Arents, A
Schmid, M
Braun, RW
Enders, G
机构
[1] Infectiol & Epidemiol EV, Medicodiagnost Lab, D-70193 Stuttgart, Germany
[2] Infectiol & Epidemiol EV, Inst Virol, D-70193 Stuttgart, Germany
关键词
LightCycler; FRET; rapid PCR; HSV-1/2;
D O I
10.1007/s150100050052
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Diagnosis of central nervous system (CNS) infection with herpes simplex virus (HSV) requires sensitive and rapid techniques. PCR therefore is considered to be the diagnostic gold standard in these cases. However, current PCR protocols are time-consuming and labor-intensive. In addition, the need for postamplification manipulations increases the risk of laboratory contaminations with amplified products. In order to improve conventional PCR techniques we compared our current semiautomated HSV-PCR-ELISA assay with a new microvolume rapid-cycle PCR system that combines real-time monitoring and fluorescence melting-curve analysis without the need for postamplification sample manipulations. Spiking experiments with supernatants of tissue culture-grown HSV type 1 (HSV-1) and type 2 (HSV-2) in HSV-negative control cerebrospinal fluid (CSF) and sterile water revealed that the new rapid cycle PCR protocol is as sensitive and specific as the PCR-ELISA. Furthermore, a mismatch (G : T) within the probe-targeted region of the HSV-2 glycoprotein B gene decreases the probe/product melting temperature (Tm) from 69 degrees C for HSV-1 to 64 degrees C for HSV-2, enabling the simultaneous identification of the two HSV genotypes by melting-curve analysis within one run. This type specificity of the system was confirmed with 30 genital swabs previously analyzed for the presence of HSV-1/2 in cell culture. While our current PCR-ELISA method needs up to 1 day from sample preparation to result generation, the new procedure takes only 1 h. We consider this system as a promising new tool for the analysis of HSV DNA in CSF and in other human body fluids as well as for the diagnosis of other infectious agents where rapid diagnosis, high sensitivity and specificity are required.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 36 条
[1]   BASE-BASE MISMATCHES - THERMODYNAMICS OF DOUBLE HELIX FORMATION FOR DCA3XA3G + DCT3YT3G (X, Y = A,C,G,T) [J].
ABOULELA, F ;
KOH, D ;
TINOCO, I ;
MARTIN, FH .
NUCLEIC ACIDS RESEARCH, 1985, 13 (13) :4811-4824
[2]  
[Anonymous], [No title captured]
[3]   RAPID DIAGNOSIS OF HERPES-SIMPLEX ENCEPHALITIS BY NESTED POLYMERASE CHAIN-REACTION ASSAY OF CEREBROSPINAL-FLUID [J].
AURELIUS, E ;
JOHANSSON, B ;
SKOLDENBERG, B ;
STALAND, A ;
FORSGREN, M .
LANCET, 1991, 337 (8735) :189-192
[4]   Integrated amplification and detection of the C677T point mutation in the methylenetetrahydrofolate reductase gene by fluorescence resonance energy transfer and probe melting curves [J].
Bernard, PS ;
Lay, MJ ;
Wittwer, CT .
ANALYTICAL BIOCHEMISTRY, 1998, 255 (01) :101-107
[5]   Homogeneous multiplex genotyping of hemochromatosis mutations with fluorescent hybridization probes [J].
Bernard, PS ;
Ajioka, RS ;
Kushner, JP ;
Wittwer, CT .
AMERICAN JOURNAL OF PATHOLOGY, 1998, 153 (04) :1055-1061
[6]   INFLUENCE OF PH ON THE CONFORMATION AND STABILITY OF MISMATCH BASE-PAIRS IN DNA [J].
BROWN, T ;
LEONARD, GA ;
BOOTH, ED ;
KNEALE, G .
JOURNAL OF MOLECULAR BIOLOGY, 1990, 212 (03) :437-440
[7]   A nested-PCR assay for the simultaneous amplification of HSV-1, HSV-2, and HCMV genomes in patients with presumed herpetic CNS infections [J].
Cassinotti, P ;
Siegl, G .
JOURNAL OF VIROLOGICAL METHODS, 1998, 71 (01) :105-114
[8]   THERMODYNAMIC COMPARISON OF THE BASE-PAIRS FORMED BY THE CARCINOGENIC LESION O-6-METHYLGUANINE WITH REFERENCE BOTH TO WATSON-CRICK PAIRS AND TO MISMATCHED PAIRS [J].
GAFFNEY, BL ;
JONES, RA .
BIOCHEMISTRY, 1989, 28 (14) :5881-5889
[9]  
Hirsch HH, 1999, J MED VIROL, V57, P31, DOI 10.1002/(SICI)1096-9071(199901)57:1&lt
[10]  
31::AID-JMV5&gt