Successful results of a bipolar active fixation lead for atrial application: An interim analysis

被引:5
作者
Buys, EM
Van Hemel, NM
Jessurun, ER
Poot, B
Kelder, JC
Defauw, JJAM
机构
[1] St Antonius Hosp, Dept Cardiol, NL-3435 CM Nieuwegein, Netherlands
[2] St Antonius Hosp, Dept Clin Cardiac Pacing, NL-3435 CM Nieuwegein, Netherlands
[3] St Antonius Hosp, Dept Cardiothorac Surg, NL-3435 CM Nieuwegein, Netherlands
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2000年 / 23卷 / 04期
关键词
atrial pacing and sensing; active fixation;
D O I
10.1111/j.1540-8159.2000.tb00834.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Adequate atrial lead performance consists of stable sensing and pacing properties. To evaluate whether the CPI 4269 bipolar lead, covered with mannitol (Sweet Tip), in the atrial position encounters these properties, we performed a prospective study of this lead. After complete dissolution of the mannitol helix, mapping of the atrium to obtain the highest electrogram and lowest threshold was followed by screw-in into the endocardium. Intraoperative measurements were performed and long-term follow-up was scheduled every 6 to 12 months to measure threshold and perform an intracardial electrogram. Between February 1993 and December 1996, a total number of 73 leads in the atrial position in a consecutive series of patients was implanted. Implantation was performed in 28 patients receiving an AAIR and 45 patients a DDDR pacemaker. Reason for pacemaker implantation was a third-degree AV block in 37% of patients, type ii second-degree AV block in 25%, sick sinus syndrome in 35%, and drug refractory paroxysmal atrial fibrillation following His-bundle ablation in 3%. The intraoperative bipolar atrial electrogram had a mean voltage of 4.25 +/- 2.1 mV. The acute atrial bipolar threshold was 0.63 +/- 0.43 V, and current was 1.35 +/- 0.81 mA at a 1.0-ms pulse duration. The mean acute resistance of the lead was 572 +/- 86 Ohm. After a mean follow-up of 18.3 months, the bipolar intracardial electrogram was 3.37 +/- 2.00 mV, the mean atrial threshold measured at the last outpatient clinic visit was 0.99 +/- 0.74 V and the mean impedance was 640 +/- 127 Ohm. A sensing problem due to traction of the atrial lead occurred in only one patient. Acute and late dislodgement did not occur. The CPI 4269 (Sweet Tip) lead is manufactured with a dissolvable capsule covering the helix tip electrode, permitting a safe passage through the venous system. This interim analysis shows that this lead in the atrial position has favorable acute and chronic results.
引用
收藏
页码:499 / 503
页数:5
相关论文
共 18 条
  • [1] BAROLD SS, 1981, PROG CARDIOVASC DIS, V24, P1
  • [2] UNSATISFYING RESULTS IN LONG-TERM ATRIAL-PACING WITH A BIPOLAR ACTIVE FIXATION ATRIAL LEAD
    BUYS, EM
    VANHEMEL, NM
    KELDER, JC
    VANDESSEL, PFHM
    BAKEMA, L
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (12): : 2292 - 2296
  • [3] A NEW STEROID-ELUTING SCREW-IN ELECTRODE
    FROHOLIG, G
    SCHWAAB, B
    SCHWERDT, H
    LAWALL, P
    TRENDELENBURG, M
    SCHIEFFER, H
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (06): : 1134 - 1142
  • [4] DECREASING ELECTRODE SIZE AND INCREASING EFFICIENCY OF CARDIAC STIMULATION
    FURMAN, S
    PARKER, B
    ESCHER, DJW
    [J]. JOURNAL OF SURGICAL RESEARCH, 1971, 11 (03) : 105 - &
  • [5] Hua W, 1996, EUR JPE, V6, P99
  • [6] ACTIVE FIXATION ATRIAL LEADS - RANDOMIZED COMPARISON OF 2 LEAD DESIGNS
    KAY, GN
    ANDERSON, K
    EPSTEIN, AE
    PLUMB, VJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (08): : 1355 - 1361
  • [7] Bipolar active fixation atrial leads: Comparison of two new lead models
    Kindermann, M
    Schwaab, B
    Frohlig, G
    Lawall, P
    Schieffer, H
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11): : 2285 - 2290
  • [8] Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing
    Lamas, GA
    Orav, J
    Stambler, BS
    Ellenbogen, KA
    Sgarbossa, EB
    Huang, SKS
    Marinchak, RA
    Estes, NAM
    Mitchell, GF
    Lieberman, EH
    Mangione, CM
    Goldman, L
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (16) : 1097 - 1104
  • [9] MOND HG, 1992, PACE, V15, P95
  • [10] ATRIAL-PACING LEADS - THE CLINICAL CONTRIBUTION OF STEROID ELUTION
    MOND, HG
    HUA, W
    WANG, CC
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (09): : 1601 - 1608