A new cerium (III)-selective membrane electrode based on 2-aminobenzothiazole

被引:56
作者
Akhond, M [1 ]
Najafi, MB [1 ]
Tashkhourian, J [1 ]
机构
[1] Shiraz Univ, Dept Chem, Coll Sci, Shiraz 71454, Iran
关键词
cerium (III) ion-selective electrode; 2-aminobenzothiazole; PVC membrane; potentiometry;
D O I
10.1016/j.snb.2003.12.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new poly(vinyl chloride) (PVC) membrane electrode based on 2-aminobenzothiazole and oleic acid (OA) as a good lipophilic additive for highly selective determination of Ce3+ ion has been developed. The electrode exhibits a Nernstian slope of 19.6 +/- 1.0 mV per decade over wide Ce3+ ion concentration range from 2.0 x 10(-6) to 2.0 x 10(-2) M and low detection limit 1.8 x 10(-6) M. The electrode possesses a fast response time of similar to13 s, relatively long lifetime (at least 3 month). The proposed electrode revealed excellent selectivity for Ce3+ over a wide variety of alkali, alkaline earth, some transitions, and heavy metal ions. The electrode could be used in a pH range of 4.1-7.3. The practical utility of the electrode has been demonstrated by its usage as an indicator electrode in potentiometric titration of oxalate (C2O42-) and fluoride (F-) ions with Ce3+ solution. The proposed electrode was also successfully applied to the determination of F- ion in mouthwash solution. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:410 / 415
页数:6
相关论文
共 38 条
[31]  
2-0
[32]   Copper(II)-selective membrane electrode based on a recently synthesized macrocyclic diamide [J].
Shamsipur, M ;
Rouhani, S ;
Ganjali, MR ;
Eshghi, H ;
Sharghi, H .
MICROCHEMICAL JOURNAL, 1999, 63 (02) :202-210
[33]   PVC-based 1,3,5-trithiane sensor for cerium(III) ions [J].
Shamsipur, M ;
Yousefi, M ;
Ganjali, MR .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2391-2394
[34]   Large improvement of the lower detection limit of ion-selective polymer membrane electrodes [J].
Sokalski, T ;
Ceresa, A ;
Zwickl, T ;
Pretsch, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (46) :11347-11348
[35]   SELECTIVITY COEFFICIENTS FOR ION-SELECTIVE ELECTRODES - RECOMMENDED METHODS FOR REPORTING K-A,B(POT) VALUES - (TECHNICAL REPORT) [J].
UMEZAWA, Y ;
UMEZAWA, K ;
SATO, H .
PURE AND APPLIED CHEMISTRY, 1995, 67 (03) :507-518
[36]   Potentiometric selectivity coefficients of ion-selective electrodes Part I.: Inorganic cations -: (Technical report) [J].
Umezawa, Y ;
Bühlmann, P ;
Umezawa, K ;
Tohda, K ;
Amemiya, S .
PURE AND APPLIED CHEMISTRY, 2000, 72 (10) :1851-2082
[37]   Additive-salt effect on low detection limit and slope sensitivity in response of potassium- and sodium-selective neutral carrier based electrodes and their liquid-membrane based ion-sensitive field-effect transistor [J].
Wakida, S ;
Masadome, T ;
Imato, T ;
Shibutani, Y ;
Yakabe, K ;
Shono, T ;
Asano, Y .
ANALYTICAL SCIENCES, 1999, 15 (01) :47-51
[38]   Lead-selective membrane electrodes based on dithiophenediazacrown ether derivatives [J].
Yang, XH ;
Kumar, N ;
Chi, H ;
Hibbert, DB ;
Alexander, PW .
ELECTROANALYSIS, 1997, 9 (07) :549-553