Agreement between radiological and computer navigation measurement of lower limb alignment

被引:30
作者
Dexel, Julian [1 ]
Kirschner, Stephan [1 ]
Guenther, Klaus-Peter [1 ]
Luetzner, Joerg [1 ]
机构
[1] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dept Orthopaed Surg, D-01307 Dresden, Germany
关键词
Knee arthroplasty; Long-leg standing radiograph; Navigation; Limb alignment; TOTAL KNEE ARTHROPLASTY; HIGH TIBIAL OSTEOTOMY; ASSISTED NAVIGATION; LOWER-EXTREMITY; RADIOGRAPHIC MEASURES; INTRAOBSERVER ERRORS; REGISTRATION PROCESS; VARUS GONARTHROSIS; CORONAL ALIGNMENT; LONG-TERM;
D O I
10.1007/s00167-013-2599-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Accurate and reproducible measurements of limb alignment are necessary for planning, performing and evaluation of reconstructive knee surgery. Aim of this study was the comparison of the alignment measured on long-leg standing radiographs with the intraoperative data from a navigation system. The records of 135 consecutive patients who received computer-assisted TKA were examined. Technical quality of the long-leg radiographs (LLRs) was classified good, acceptable or poor according to the rotation of the leg. The difference between radiographic and navigation measurements of leg alignment was assessed. Preoperative LLRs were rated as good 56.3 % (71.1 % postoperatively), acceptable in 37.0 % (20.0 % postoperatively) and poor in 6.7 % (8.9 % postoperatively). The median difference between radiographic and navigation measurements increased with reduced quality of the LLR [good 1.5A degrees (range 0.0A degrees-9.9A degrees), acceptable 2.5A degrees (range 0.0A degrees-15.0A degrees), poor 4.5A degrees (range 0.2A degrees-9.5A degrees)], but not with greater deformity. Median difference between both measurements in good radiographs was 1.7A degrees (range 0.0A degrees-9.9A degrees) preoperatively and 1.2A degrees (range 0.0A degrees-7.0A degrees) postoperatively. Difference between radiographic and navigation measurements of lower limb alignment is low if the LLR are obtained in neutral rotation. Larger differences between both measurements can occur even under these ideal conditions, and it is still unclear which measurement is closer to reality. Therefore, even if a navigation system is used during surgery, long-leg standing radiographs should currently not be abandoned. III.
引用
收藏
页码:2721 / 2727
页数:7
相关论文
共 48 条
[1]
The long leg radiograph is a reliable method of assessing alignment when compared to computer-assisted navigation and computer tomography [J].
Babazadeh, Sina ;
Dowsey, Michelle M. ;
Bingham, Roger J. ;
Ek, Eugene T. ;
Stoney, James D. ;
Choong, Peter F. M. .
KNEE, 2013, 20 (04) :242-249
[2]
Bäthis H, 2006, ORTHOPADE, V35, P1056, DOI 10.1007/s00132-006-1001-3
[3]
Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Perlick, C ;
Grifka, J .
INTERNATIONAL ORTHOPAEDICS, 2004, 28 (02) :87-90
[4]
Brouwer R W, 2007, J Knee Surg, V20, P210
[5]
Clemens Ulrich, 2003, Surg Technol Int, V11, P265
[6]
A QUANTITATIVE APPROACH TO RADIOGRAPHY OF THE LOWER-LIMB - PRINCIPLES AND APPLICATIONS [J].
COOKE, TDV ;
SCUDAMORE, RA ;
BRYANT, JT ;
SORBIE, C ;
SIU, D ;
FISHER, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :715-720
[7]
PROXIMAL TIBIAL OSTEOTOMY - A CRITICAL LONG-TERM STUDY OF 87 CASES [J].
COVENTRY, MB ;
ILSTRUP, DM ;
WALLRICHS, SL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (02) :196-201
[8]
Delp SL, 1998, CLIN ORTHOP RELAT R, P49
[9]
Derek T, 2007, J RHEUMATOL, V34, P1796