A sonotrode for electroanalysis: the determination of copper in passivating media

被引:13
作者
Floate, S
Hardcastle, JL
Cordemans, E
Compton, RG
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[2] Undatim Ultrason SA, B-1400 Nivelles, Belgium
关键词
D O I
10.1039/b202883m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sonotrode consisting of a disc shaped glassy carbon electrode attached to a quartz rod and inserted into a drilled ultrasonic probe tip has been designed and used as a novel alternative to the traditional 'face on' cell arrangement where an ultrasonic micro-tip probe is placed opposite a glassy carbon working electrode. The 'single probe' arrangement is both convenient and optimised for electroanalysis. We first report how under ultrasonic agitation of the sonotrode the mass transport to the electrode surface is enhanced compared to that observed under silent conditions and also how the sonotrode cell geometry compares with the well-established 'face on' cell geometry for cobalt electrodeposition. Second, we will show that the new sonotrode can be used in the application for the determination of copper in a series of fouling media in which conventional silent electroanalysis fails. The passivation of the electrodes surface by surfactant species can be overcome by cavitationally induced streaming and/or erosion at the sonotrode surface with recoveries of 100% and 93.8% achieved at 42 W cm(-2) for Triton(R) X-100 and sodium dodecyl sulfate (SDS), respectively. Other data indicates that the sonotrode can be successfully employed for the detection of copper in beer (Marston's bitter), a system known to be complex and highly electrode fouling and difficult to analyse using standard, silent electroanalytical techniques.
引用
收藏
页码:1094 / 1099
页数:6
相关论文
共 56 条
[1]   Anodic stripping voltammetry of copper at insonated glassy carbon-based electrodes:: application to the determination of copper in beer [J].
Agra-Gutiérrez, C ;
Hardcastle, JL ;
Ball, JC ;
Compton, RG .
ANALYST, 1999, 124 (07) :1053-1057
[2]  
Agra-Gutierrez C, 1998, ELECTROANAL, V10, P603, DOI 10.1002/(SICI)1521-4109(199807)10:9<603::AID-ELAN603>3.3.CO
[3]  
2-D
[4]  
AGRAGUTIERREZ C, 1989, ANALYST, V10, P204
[5]  
Akkermans RP, 1998, ELECTROANAL, V10, P814, DOI 10.1002/(SICI)1521-4109(199809)10:12<814::AID-ELAN814>3.0.CO
[6]  
2-W
[7]   Sono-electroanalysis: Application to the detection of lead in wine [J].
Akkermans, RP ;
Ball, JC ;
Rebbitt, TO ;
Marken, F ;
Compton, RG .
ELECTROCHIMICA ACTA, 1998, 43 (23) :3443-3449
[8]  
Akkermans RP, 1998, ELECTROANAL, V10, P613, DOI 10.1002/(SICI)1521-4109(199807)10:9<613::AID-ELAN613>3.3.CO
[9]  
2-9
[10]   THE EFFECT OF ULTRASOUND ON MASS-TRANSPORT TO A MICROELECTRODE [J].
BIRKIN, PR ;
SILVAMARTINEZ, S .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1995, (17) :1807-1808