Continuous free-flap monitoring with tissue-oxygen measurements: Three-year experience

被引:63
作者
Kamolz, LP [1 ]
Giovanoli, P [1 ]
Haslik, W [1 ]
Koller, R [1 ]
Frey, M [1 ]
机构
[1] Univ Vienna, Sch Med, Div Plast & Reconstruct Surg, Dept Surg, A-1090 Vienna, Austria
关键词
free tissue transfer; free flap monitoring; tissue oxygen measurements; Licox (R) probe;
D O I
10.1055/s-2002-33319
中图分类号
R61 [外科手术学];
学科分类号
摘要
Early recognition of flap failure is a prerequisite for flap salvage. Many methods are used to monitor free flaps. The time interval for re-establishing vascular patency is the limiting factor for a successful revision. Prompt re-operation and a rapid and sufficient correction of the microvascular anastomosis are necessary to maintain flap viability. The Licox Catheter pO(2) Micro-Probe instrument is used for continuous determination of oxygen partial pressure (pO(2)) in body fluids and tissue (p(ti)O(2)). Over a period of 3 years, 60 free tissue transfers to head and neck, trunk, and upper and lower extremities were monitored using the Licox Catheter Probe System. The flexible Licox Catheter pO(2) Micro-Probe detected circulatory changes and failure in all cases, with no false positives or negatives. In all cases in which the arterial pedicle failed, the p(ti)O(2) dropped rapidly; in cases of venous insufficiency, the p(ti)O(2) value decreased more or less slowly. In all failing flaps, a p(ti)O(2) decrease of 10 mmHg within a half-hour, or a p(ti)O(2) drop below 10 mmHg was observed. These are observations which are useful as precise indicators for vascular complications and flap failure. Based on the authors' observations and data, the Licox probe is a sensitive and accurate monitoring system for all types of free flaps.
引用
收藏
页码:487 / 491
页数:5
相关论文
共 26 条
[1]  
BIEMER E, 1981, INT SURG, V66, P37
[2]  
Disa JJ, 1999, PLAST RECONSTR SURG, V104, P97, DOI 10.1097/00006534-199907000-00014
[3]  
FREY M, 1983, Handchirurgie Mikrochirurgie Plastische Chirurgie, V15, P96
[4]   Green light photoplethysmography monitoring of free flaps [J].
Futran, ND ;
Stack, BC ;
Hollenbeak, C ;
Scharf, JE .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2000, 126 (05) :659-662
[5]   TEMPERATURE LOAD TEST TO INCREASE THE ACCURACY OF LASER DOPPLER MONITORING OF FLAPS [J].
HEDEN, P ;
ARNANDER, C .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1992, 26 (01) :29-32
[6]   THE ROLE OF EMERGENT EXPLORATION IN FREE-TISSUE TRANSFER - A REVIEW OF 150 CONSECUTIVE CASES [J].
HIDALGO, DA ;
JONES, CS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 86 (03) :492-498
[7]  
Hirigoyen MB, 1995, MICROSURG, V16, P723, DOI 10.1002/micr.1920161103
[8]   MYOCUTANEOUS FLAP ISCHEMIA - FLOW DYNAMICS FOLLOWING VENOUS AND ARTERIAL-OBSTRUCTION [J].
HJORTDAL, VE ;
HANSEN, ES ;
HAUGE, E .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 89 (06) :1083-1091
[9]   DIFFERENTIAL-EFFECTS OF VENOUS STASIS AND ARTERIAL INSUFFICIENCY ON TISSUE OXYGENATION IN MYOCUTANEOUS ISLAND FLAPS - AN EXPERIMENTAL-STUDY IN PIGS [J].
HJORTDAL, VE ;
HAUGE, E ;
HANSEN, ES .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 89 (03) :521-529
[10]   ROUTINE USE OF LASER DOPPLER FLOWMETRY FOR MONITORING AUTOLOGOUS TISSUE-TRANSPLANTS [J].
JENKINS, S ;
SEPKA, R ;
BARWICK, WJ .