Pedicle screw motion in the osteoporotic spine after augmentation with laminar hooks, sublaminar wires, or calcium phosphate cement: A comparative analysis

被引:59
作者
Tan, JS
Kwon, BK
Dvorak, MF
Fisher, CG
Oxland, TR
机构
[1] Univ British Columbia, Div Orthopaed Engn Res, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Combined Neurosurg & Orthopaed Spine Program, Dept Mech Engn, Vancouver, BC V5Z 1M9, Canada
[3] Univ British Columbia, Combined Neurosurg & Orthopaed Spine Program, Dept Orthopaed, Vancouver, BC V5Z 1M9, Canada
[4] Vancouver Coastal Hlth Res Inst, Vancouver, BC, Canada
关键词
osteoporosis; bone density; biomechanics; lumbar vertebrae; internal fixators; bone cement; calcium phosphates; spinal fusion;
D O I
10.1097/01.BRS.0000134569.63542.49
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A biomechanical study addressing the motion of pedicle screws in a human cadaveric, osteoporotic spine model. Objectives. To compare the fixation of pedicle screws in an osteoporotic spine model after augmentation with laminar hooks, sublaminar wires, or calcium phosphate cement and to determine the kinematic patterns of these screws. Summary of Background Data. Numerous techniques exist for improving the quality of fixation within the osteoporotic spine, including supplementing the construct with laminar hooks, sublaminar wires, or calcium phosphate cement. Direct comparisons of these practices, however, are lacking. Methods. Twenty-four cadaveric lumbar vertebrae were instrumented with a pedicle screw and rod construct augmented with laminar hooks, sublaminar wires, or calcium phosphate cement. The screws were tested cyclically with physiologic loads. Rigid body motions of the screws were measured using an optoelectronic camera system, and the motion at the screw tip and at the screw head were calculated. Screw motions were compared using nonparametric paired statistical analysis. Results. Between augmentation groups, there were no significant differences in the magnitude of motion at the screw head and at the screw tip. After calcium phosphate cement supplementation, screw motion was predominantly rotational in nature, whereas rigid body translation of the screw was more common with sublaminar wires or laminar hooks. Conclusions. The three augmentation techniques were similar in their ability to enhance the rigidity of fixation of the pedicle screws. Differences did exist, however, in the patterns of pedicle screw motion, with the calcium phosphate cement augmentation resulting in less rigid body translation than the other two techniques.
引用
收藏
页码:1723 / 1730
页数:8
相关论文
共 36 条
  • [1] An Y. H., 2002, INTERNAL FIXATION OS, P73
  • [2] *ASTM, 2001, F1717 ASTM INT
  • [3] An experimental study of lumbar destabilization - Restabilization and bone density
    Bennett, GJ
    Serhan, HA
    Sorini, PM
    Willis, BH
    [J]. SPINE, 1997, 22 (13) : 1448 - 1453
  • [4] Future directions - Augmentation of osteoporotic vertebral bodies
    Bostrom, MPG
    Lane, JM
    [J]. SPINE, 1997, 22 (24) : 38S - 42S
  • [5] THE STRENGTH AND STIFFNESS OF THORACIC IMPLANT ANCHORS IN OSTEOPOROTIC SPINES
    BUTLER, TE
    ASHER, MA
    JAYARAMAN, G
    NUNLEY, PD
    ROBINSON, RG
    [J]. SPINE, 1994, 19 (17) : 1956 - 1962
  • [6] CLOWARD RB, 1985, CLIN ORTHOP RELAT R, P16
  • [7] INFLUENCE OF BONE-MINERAL DENSITY ON THE FIXATION OF THORACOLUMBAR IMPLANTS - A COMPARATIVE-STUDY OF TRANSPEDICULAR SCREWS, LAMINAR HOOKS, AND SPINOUS PROCESS WIRES
    COE, JD
    WARDEN, KE
    HERZIG, MA
    MCAFEE, PC
    [J]. SPINE, 1990, 15 (09) : 902 - 907
  • [8] Cook S D, 2001, Spine J, V1, P109, DOI 10.1016/S1529-9430(01)00020-1
  • [9] Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design
    Cook, SD
    Salkeld, SL
    Whitecloud, TS
    Barbera, J
    [J]. JOURNAL OF SPINAL DISORDERS, 2000, 13 (03): : 230 - 236
  • [10] STATIC AND CYCLICAL BIOMECHANICAL ANALYSIS OF PEDICLE SCREW SPINAL CONSTRUCTS
    CUNNINGHAM, BW
    SEFTER, JC
    SHONO, Y
    MCAFEE, PC
    [J]. SPINE, 1993, 18 (12) : 1677 - 1688