Increased accumulation of magnetic nanoparticles by magnetizable implant materials for the treatment of implant-associated complications

被引:6
作者
Angrisani, Nina [1 ]
Foth, Franziska [1 ]
Kietzmann, Manfred [2 ]
Schumacher, Stephan [2 ]
Angrisani, Gian Luigi [3 ]
Christel, Anne [4 ]
Behrens, Peter [4 ]
Reifenrath, Janin [1 ]
机构
[1] Univ Vet Med, Small Anim Clin, D-30559 Hannover, Germany
[2] Univ Vet, Inst Pharmacol Toxicol & Pharm, D-30559 Hannover, Germany
[3] Univ Hannover, Inst Mat Sci, D-30823 Garbsen, Germany
[4] Leibniz Univ Hannover, Inst Inorgan Chem, D-30167 Hannover, Germany
关键词
Implant directed magnetic drug targeting; Martensitic steel; In vitro; Magnetic field strength; DRUG-DELIVERY; EFFICIENT; CAPTURE; CELLS;
D O I
10.1186/1477-3155-11-34
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 [微生物学]; 090105 [作物生产系统与生态工程];
摘要
Background: In orthopaedic surgery, accumulation of agents such as anti-infectives in the bone as target tissue is difficult. The use of magnetic nanoparticles (MNPs) as carriers principally enables their accumulation via an externally applied magnetic field. Magnetizable implants are principally able to increase the strength of an externally applied magnetic field to reach also deep-seated parts in the body. Therefore, the integration of bone-addressed therapeutics in MNPs and their accumulation at a magnetic orthopaedic implant could improve the treatment of implant related infections. In this study a martensitic steel platelet as implant placeholder was used to examine its accumulation and retention capacity of MNPs in an in vitro experimental set up considering different experimental frame conditions as magnet quantity and distance to each other, implant thickness and flow velocity. Results: The magnetic field strength increased to approximately 112% when a martensitic stainless steel platelet was located between the magnet poles. Therewith a significantly higher amount of magnetic nanoparticles could be accumulated in the area of the platelet compared to the sole magnetic field. During flushing of the tube system mimicking the in vivo blood flow, the magnetized platelet was able to retain a higher amount of MNPs without an external magnetic field compared to the set up with no mounted platelet during flushing of the system. Generally, a higher flow velocity led to lower amounts of accumulated MNPs. A higher quantity of magnets and a lower distance between magnets led to a higher magnetic field strength. Albeit not significantly the magnetic field strength tended to increase with thicker platelets. Conclusion: A martensitic steel platelet significantly improved the attachment of magnetic nanoparticles in an in vitro flow system and therewith indicates the potential of magnetic implant materials in orthopaedic surgery. The use of a remanent magnetic implant material could improve the efficiency of capturing MNPs especially when the external magnetic field is turned off thus facilitating and prolonging the effect. In this way higher drug levels in the target area might be attained resulting in lower inconveniences for the patient.
引用
收藏
页数:10
相关论文
共 40 条
[1]
Analysis of magnetic drug carrier particle capture by a magnetizable intravascular stent: 1. Parametric study with single wire correlation [J].
Chen, HT ;
Ebner, AD ;
Rosengart, AJ ;
Kaminski, MD ;
Ritter, JA .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2004, 284 :181-194
[2]
Magnetic nanoparticles and targeted drug delivering [J].
Chomoucka, Jana ;
Drbohlavova, Jana ;
Huska, Dalibor ;
Adam, Vojtech ;
Kizek, Rene ;
Hubalek, Jaromir .
PHARMACOLOGICAL RESEARCH, 2010, 62 (02) :144-149
[3]
Antimicrobial approaches for preventing infections associated with surgical implants [J].
Darouiche, RO .
CLINICAL INFECTIOUS DISEASES, 2003, 36 (10) :1284-1289
[4]
Validation of high gradient magnetic field based drug delivery to magnetizable implants under flow [J].
Forbes, Zachary G. ;
Yellen, Benjamin B. ;
Halverson, Derek S. ;
Fridman, Gregory ;
Barbee, Kenneth A. ;
Friedman, Gary .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (02) :643-649
[5]
Antibiotic-impregnated articulating cement spacer for infected total knee arthroplasty [J].
Garg, Parag ;
Ranjan, Rajeev ;
Bandyopadhyay, Utpal ;
Chouksey, Shiv ;
Mitra, S. R. ;
Gupta, Samar K. .
INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (06) :535-540
[6]
Gollwitzer H, 2003, TRAUMA BERUFSKRANKH, V5, P347
[7]
Lactoferrin and ceruloplasmin derivatized superparamagnetic iron oxide nanoparticles for targeting cell surface receptors [J].
Gupta, AK ;
Curtis, ASG .
BIOMATERIALS, 2004, 25 (15) :3029-3040
[8]
THE MANAGEMENT OF OPEN FRACTURES [J].
GUSTILO, RB ;
MERKOW, RL ;
TEMPLEMAN, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (02) :299-304
[9]
Femur window -: a new approach to microcirculation of living bone in situ [J].
Hansen-Algenstaedt, N ;
Schaefer, C ;
Wolfram, L ;
Joscheck, C ;
Schroeder, M ;
Algenstaedt, P ;
Rüther, W .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (05) :1073-1082
[10]
Analysis of Trajectories for Targeting of Magnetic Nanoparticles in Blood Vessels [J].
Heidsieck, Alexandra ;
Vosen, Sarah ;
Zimmermann, Katrin ;
Wenzel, Daniela ;
Gleich, Bernhard .
MOLECULAR PHARMACEUTICS, 2012, 9 (07) :2029-2038