EOG correction: comparing different calibration methods, and determining the number of epochs required in a calibration average

被引:13
作者
Croft, RJ [1 ]
Barry, RJ [1 ]
机构
[1] Univ Wollongong, Dept Psychol, Wollongong, NSW 2522, Australia
关键词
EEG; EOG; correction; regression; aligned-artifact average; NERP;
D O I
10.1016/S1388-2457(99)00256-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: A form of EOG correction called the 'aligned-artifact average' (AAA) method has been advanced by the authors. In contrast to many previous methods, this used a correction coefficient (B), based on an average of eye movements rather than raw data, to remove eye movement related contamination from the EEG. The first part of this study was aimed at determining whether a variation of this procedure that is more easily implemented would produce a similar correction. The second pan was designed to determine the number of epochs needed in an average to correct adequately. Methods: Subjects performed a series of eye movement tasks whilst EEG and EOG data were recorded. Data were manipulated according to either the AAA or an alternate new ERP method (NERP) and the resultant Bs were compared in part A. In part B, averages were created from varying numbers of epochs, and the resultant r(2)-values were compared. Results: The AAA and NERP methods produced the same Ss, and averages with at least 40 epochs were required for adequate B estimation for both VEOG and HEOG. Conclusion: There is no difference between the AAA and NERP methods and thus it is acceptable to use the more easily implemented NERP method for EOG correction. Lt is recommended that when applying this procedure, at least 40 epr,chs should be used to make up the averages from which to calculate correction coefficients. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:440 / 443
页数:4
相关论文
共 7 条
[1]   EOG correction: a new aligned-artifact average solution [J].
Croft, RJ ;
Barry, RJ .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 107 (06) :395-401
[2]   EOG correction: a new perspective [J].
Croft, RJ ;
Barry, RJ .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 107 (06) :387-394
[3]   THE DELETERIOUS EFFECT OF OCULAR ARTIFACTS ON THE QUANTITATIVE EEG, AND A REMEDY [J].
GASSER, T ;
ZIEGLER, P ;
GATTAZ, WF .
EUROPEAN ARCHIVES OF PSYCHIATRY AND CLINICAL NEUROSCIENCE, 1992, 241 (06) :352-356
[4]   THE CORRECTION OF EOG ARTIFACTS BY FREQUENCY-DEPENDENT AND FREQUENCY INDEPENDENT METHODS [J].
GASSER, T ;
SROKA, L ;
MOCKS, J .
PSYCHOPHYSIOLOGY, 1986, 23 (06) :704-712
[5]   EYE MOVEMENT ARTIFACT IN CNV [J].
HILLYARD, SA ;
GALAMBOS, R .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1970, 28 (02) :173-&
[6]   A SOLUTION FOR RELIABLE AND VALID REDUCTION OF OCULAR ARTIFACTS, APPLIED TO THE P300 ERP [J].
SEMLITSCH, HV ;
ANDERER, P ;
SCHUSTER, P ;
PRESSLICH, O .
PSYCHOPHYSIOLOGY, 1986, 23 (06) :695-703
[7]   THE REMOVAL OF THE EYE-MOVEMENT ARTIFACT FROM THE EEG BY REGRESSION-ANALYSIS IN THE FREQUENCY-DOMAIN [J].
WOESTENBURG, JC ;
VERBATEN, MN ;
SLANGEN, JL .
BIOLOGICAL PSYCHOLOGY, 1983, 16 (1-2) :127-147