Determination of trace iron in beer using flow injection systems with in-valve column and bead injection

被引:30
作者
Ampan, P
Lapanantnoppakhun, S
Sooksamiti, P
Jakmunee, J
Hartwell, SK
Jayasvati, S
Christian, GD
Grudpan, K [1 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Chiang Mai 50200, Thailand
[2] Off Mineral Resources Reg III, Chiang Mai 50200, Thailand
[3] Chiang Mai Univ, Inst Sci & Technol Res & Dev, Chiang Mai 50200, Thailand
[4] Chiang Mai Univ, Fac Med, Dept Radiol, Chiang Mai 50200, Thailand
[5] Univ Washington, Dept Chem, Seattle, WA 98195 USA
关键词
iron; beer; flow injection; bead injection; atomic absorption spectrometry; absorptiometry; spectrophotometry;
D O I
10.1016/S0039-9140(02)00446-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three flow injection (FI) systems were investigated for the determination of trace iron in beer: an FI-in-valve column-flame atomic absorption spectrophotometry (FI-FAAS) system, a spectrophotometric FI system with a column placed at the detection point, and an FI-spectrophotometric system with bead injection (FI-BI). Cationic exchange resin Dowex 50W X8 and iminodiacetate chelating resin, Chelex-100, were employed for the FI-spectrophotometric and FI-FAAS systems, respectively. The FI-in-valve column, packed with the resin, enhances the FAAS performance. The spectrophotometric FI system with a column (packed with Chelex-100) placed at the detection point (in a cell holder of a spectrophotometer) is based on the formation of iron (II)-1,10-phenanthroline complex sorbed onto the resin. No eluent has been found to be suitable. The FI-BI for renewable microcolumn has been proven to be an alternative. The FI-FAAS and FI-BI procedures provide online sample preseparation and preconcentration for the determination of iron in beer. Both are simple, rapid, and economical. The procedures also involve sample preparation (decarbonation and suppression of tannin interference by adding ascorbic acid) and standard addition. The results obtained by FI-FAAS and FI-BI agree with those of AOAC spectrophotometric method. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1327 / 1334
页数:8
相关论文
共 29 条
[1]   FLOW PROCEDURE FOR ION-EXCHANGE PRECONCENTRATION AND ONLINE SPECTROPHOTOMETRIC DETERMINATION OF IRON(III) AS ITS THIOCYANATE COMPLEX [J].
ALMUAIBED, AM ;
TOWNSHEND, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (06) :601-602
[2]  
CUNNIFF P, 1997, OFF METH AN AOAC INT, P27
[3]   DETERMINATION OF IRON AT NG/ML LEVEL BY SOLID-PHASE SPECTROPHOTOMETRY AFTER PRECONCENTRATION ON CATION-EXCHANGE FILTERS [J].
GARCIA, FC ;
CHECA, R ;
AVIDAD, R ;
CAPITANVALLVEY, LF .
TALANTA, 1995, 42 (05) :711-715
[4]   Comparative contents of some phenolics in beer, red and white wines [J].
Gorinstein, S ;
Caspi, A ;
Zemser, M ;
Trakhtenberg, S .
NUTRITION RESEARCH, 2000, 20 (01) :131-139
[5]   FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF URANIUM WITH IN-VALVE ION-EXCHANGE COLUMN PRECONCENTRATION AND SEPARATION [J].
GRUDPAN, K ;
LAIWRAUNGRATH, S ;
SOOKSAMITI, P .
ANALYST, 1995, 120 (08) :2107-2110
[6]  
GRUDPAN K, 1999, SCI ASIA, V25, P99
[7]  
HERGENREDER RI, 1991, ATOM SPECTROSC, V12, P74
[8]   Determination of iron(II) and total iron in environmental water samples by flow injection analysis with column preconcentration of chelating resin functionalized with N-hydroxyethylethylenediamine ligands and chemiluminescence detection [J].
Hirata, S ;
Yoshihara, H ;
Aihara, M .
TALANTA, 1999, 49 (05) :1059-1067
[9]   TRACE-METAL ENRICHMENT BY AUTOMATED ONLINE COLUMN PRECONCENTRATION FOR FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY [J].
HIRATA, S ;
HONDA, K ;
KUMAMARU, T .
ANALYTICA CHIMICA ACTA, 1989, 221 (01) :65-76
[10]   The kinetics and mechanisms of the reaction of iron(III) with gallic acid, gallic acid methyl ester and catechin [J].
Hynes, MJ ;
O Coinceanainn, M .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2001, 85 (2-3) :131-142